Jet Table; Cs 1034-1 - Miele CS 1012-1 Operating And Installation Instructions

Gas hobs
Table of Contents

Advertisement

Conversion to another type of gas

CS 1034-1

Nominal rating at high setting
Gas type
Small burner
Natural gas H
Liquid gas
Medium
Natural gas H
burner
Liquid gas
Large burner
Natural gas H
Liquid gas
Total output
Natural gas H
Liquid gas
Nominal rating at low setting
Gas type
Small burner
Natural gas H
Liquid gas
Medium burner
Natural gas H
Liquid gas
Large burner
Natural gas H
Liquid gas
52
Screw in the new jets according to the
following table.

Jet table

kW
For UK and IE
1.00
1.00 / 73 g/h
1.80
1.80 / 131 g/h
Natural gas H
3.00
Small burner
3.00 / 218 g/h
Medium burner
Large burner
8.80
8.80 / 640 g/h
Liquid gas
Small burner
Medium burner
Large burner
kW
The jet markings refer to 1/100 mm of
the jet diameter.
0.25
0.25
0.35
0.35
0.50
0.50
Main jet
Small jet
C
C
0.76
0.39
1.00
0.42
1.28
0.52
0.50
0.23
0.67
0.27
0.87
0.32

Advertisement

Table of Contents
loading

Table of Contents