Top view
Setscrew (loosen to
adjust horizontal
rotation)
Set focal length
(bottom)
Set focus
(top)
TECH TIP!
Document 800-07091 Rev A
07/10
HD4 EQUIP Series True Day/Night Rugged IP Network Camera User Guide
Figure 2-10
Gimbal Adjustment
Local video out
Factory reset
button
Loosen locking screw
(inside conduit entry)
to remove the side
conduit plug.
Adjusting the Lens Focus
Lenses are pre-focused at the factory. They might require a final adjustment after
installation in the unlikely event the optical effect of the dome bubble causes a slight
defocusing of the lens.
To check the focus, hold the dome bubble over the lens while making any adjustments.
Restoring Factory Defaults
Your camera has a Factory Reset button located inside the camera (see
this button to restore your camera options and passwords to their default settings. Use a
pin or straightened paperclip to press and hold the Reset button for three seconds.
Angle view
B
C
A
Legend
A = Tilt rotation
B = Horizontal rotation
C = Pan rotation
Figure
2-10). Use
29