Ex. 3 Measurement 1 Point sensor
• 8 points are handled by 1 byte.
• Black & white = FA
(H)
1
Point No.
P7
Black & white White White White White White Black White Black
[Example of HMI]
[Output data (general purpose serial)]
Packet 0 Measurement 1
2) Measurement execution 2: code 0011
• Execute all of the measurement programs for a specified object type or corresponding
measurement program for the specified camera.
• The result data of the measurement program will be divided into packets by each 512 bytes
(128 data × 4 bytes) from the beginning, and sent as the response.
[Command]
:
Station No. 0
•
The first measurement execution command is specified as "0" for the specified packet No.
[Response]
:
Station No. 0
•
Current packet No.,
F
1
1
1
1
P6
P5
P4
P3
0 = Black, 1 = White
Registration 0 ~7
Registration 8 ~ 15
H
Executi o n
0
1
1 Object type camera
(H ) (L ) No.
0
1
1
RC RC RC RC
(H )
•••
•••
Final packet No.
Numeric value result
6 - 7
A
0
1
0
P2
P1
P0
1 bytes
1 bytes
SC SC CR
(H ) (L )
Executi o n
Object type camera
(L ) (H ) (L )
No.
SC SC CR
data
(H ) (L )
F C1 BRT