Download Print this page

Sanyo 26KHS72R Submittal Data

Wall mounted heat pump
Hide thumbs Also See for 26KHS72R:

Advertisement

Split System Submittal Data
System: 26KHS72R
Wall Mounted Heat Pump
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(RPM)
No. Motors
(High)
CFM
(A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
(RPM, High)
No. Poles
No. Motors
(W)
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
(A)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
(in.)
(in.)
Drain Connection Size
Indoor/Outdoor: KHS2672R/CH2672R
General Data (at 230V)
230/208/1/60
15-30 Indoor-Outdoor
15-30 Indoor-Outdoor
DC Rotary Inverter
(A)
12.9-17.5
Propeller
18-7/64-1
DC Motor
8 - 800
(W)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffeled
1 - 15.9
(in.)
Cross Flow
3-15/16 L33-15/64 - 1
3 & Auto
4 - 1224
559/475/390
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
2 - 24.1
1-1/4"
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
1 - 90
1765
Outdoor Unit
13.8
Weight
Net
Shipping
7.26
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
1 - 29
Latent Capacity
SEER
Dehumidification
48
0.31
Amps
Power Inputs
Outdoor Sound Rating
Heating
Total Capacity
2.57
HSPF
9/32"
Electric Expansion Valve
50 (outdoor lower), 100 (outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
12-63/64 x 44-7/8 x 8-31/32
(Crated)
15-11/32 x 47-27/32 x 11-17/32
(Uncrated)
30-23/32 x 37 x 13-3/8
(Crated)
34-31/32 x 39-31/32 x 16-3/32
Indoor
(lbs.)
40
(lbs.)
44
Indoor
(cu.ft.)
4.9
(BTU/H)
25,200 (9,500-25,200)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
(BTU/H) 29,200 (8,000-29,200)
R410A
4.19
Flare
165
3/8"
5/8"
H x W x D
Outdoor
128
148
Outdoor
13.0
14,790
10,410
14.9
8.1
15.3/16.9
2,840/2,840
49
10.2

Advertisement

loading

Summary of Contents for Sanyo 26KHS72R

  • Page 1 Print Form Split System Submittal Data System: 26KHS72R Indoor/Outdoor: KHS2672R/CH2672R Wall Mounted Heat Pump Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: General Data (at 230V) Power V/PH/Hz 230/208/1/60 Circuit Ampacity 15-30 Indoor-Outdoor Fuse Size, Max.
  • Page 2 75F DB/65F WB Maximum Indoor unit : KH3072R Heating/Cooling Automatic Changeover Built-In -DB/-WB 5F DB Minimum Self-Diagnosis Built-In Air Filter Washable, Anti-Mold Sanyo Commercial Solutions A Division of SANYO North America 1300 Michael Drive Wood Dale, IL 60191 USA www.sanyohvac.com...

This manual is also suitable for:

Khs2672rCh2672r