Function and control
5.2.6.9 Malfunction display and malfunction handling
a) For the complete appliance's malfunctions Annex 2
If there's malfunction with the outdoor unit, the light of the outdoor unit will flash and its frequency is
1HZ, the number of times is according to the table, when a round of flashing is finished, the light
shoud be off for 5 seconds.
b) For the units' malfunctins Annex 1
If there's malfunction with the units, this will not affect the run of the complete appliance, but this can
be displayed by the malfunction light, the light flashing frequency is 0.5HZ, the number of times is
according to the malfunction table of the indoor units. When a round of flashing is finished, the light
shoud be off for 10 seconds. Then report according to the order : unit A→unit B→unit C→unit D, that
is, if there's malfunction with several units, then just report the indoor unit with the highest priority level.
Among the unit malfunctions, the priority level of the communication malfunction is the highest, for
others, that appears first will have the priority.
Remarks: in 3 minutes when the compressor stops, the units' malfunctions are not displayed; the
complete appliance's malfunctions are prior to the units' malfunctions.
Annex 1 Malfunction codes of the whole unit
Remarks: under the mode of refrigeration, the malfunctions of each unit's thin pipe temperature
sensor are not reported, under the mode of heating, the malfunctions of each unit's thick pipe
temperature sensor are not reported.