Advertisement

3. Soft operation
the system enters the mode after receiving the ¡ ® soft signal¡ ¯ .
a. soft heating: the airflow speed is slight, the system sends the soft signal to the outdoor system.
b. soft cooling: the airflow speed is slight, the system sends the soft signal to the outdoor system.
When the compressor operates, the airflow speed is soft speed. EEPROM is adaptable.
soft operation can not work under the demoisturing and airflow-sending operation.
4. Health operation
After receiving the signal from the remote control,(HV series: the background lighting is green
the ¡ ® health¡ ¯
logo on. HS series: the ¡ ® health¡ ¯ indicator will be lighted). If the fan operates,
the negative ion generator operates to realize the negative sending function.
If the indoor fan stops, the negative ion generator is turned off.
When the negative ion generator is turned off, if the health system is turned on, the negative ion
generator will be turned on when the fan operates.
5. Timing.
You can set 24 hours¡ ¯
lightened. Also, the light will be turning off after the timing is finished. The followings are
several timing methods.
1.1 system /on timing: The timing indicator will be lightened and the indoor system is under
the waiting mode. The light will be turned off when the timing is finished and the rest of the system
will operate under a normal condition. The timing starts since the last reception of the timing
singal. You can have the dormacy setting under the timing mode, the order of your settings will
be operated according to the timing settings.
1.2 system /off timing: When the system is turned on, the timing indicator is lightened, the rest
of the system will operated under a normal condition. When set time comes, the indicator light will
be turned off and the system will be turned off. If you have set the dormant functions, the order
of your settings will be operated according to the timing settings.
1.3 system /on and off timing: The settings will be completed according to the orders.
6. sleep operation
The sleep timing is an eight hours unadaptable one. The timing signs are shown on the V series board. (RC series
show the sleep logo, HS series the timing light is lighted).
2.1 Under the cooling/ demoisture operation, after the setting of the sleep operation, the set temperature
will be raised for 1 centigrade after 1 hour's operation and will be raised for 1 centigrade 1 hour later. The
system will keep this status for 6 hours and then close.
2.2 Under the heating mode, after the setting of the sleep operation, the et temperature will fall 2 centigrades
after 1 hour's operation and will fall 2 centigrades 1 hours later. 3 hours after the preceding operations, the
set temperature will be raised for 1 centigrade and the system will keep this status for 3 hours and then close
down.
2.3 During the dormant time, except the change of the system mode or a new press on the dormant setting keys,
the timing of the 8 hours dormancy will take the first timing as the start time, any presses on other keys will
not affect the original timing.
2.4 Indoor fan control under the sleep operation.
If the indoor fan is at the high speed before the sleep operation setting, the speed will be turned to medium after
on/off timing accordingly. After the setting, the timing indicator will be