Intermec CK70 User Manual page 153

70 series
Hide thumbs Also See for CK70:
Table of Contents

Advertisement

Symbology
Density
Code 39
0.08 mm (3 mils)
0.1 mm (2.8 mils)
0.25 mm (10 mils)
0.5 mm (20 mils)
1 mm (40 mils)
1.3 mm (51 mils)
EAN 100%
0.33 mm (13 mils)
70 Series Mobile Computer User Manual
EX25 Near-Far Range Imager Minimum Reading
Distance
Minimum reading distances are measured in the dark (0 lux). The
following graphic does not include the 0.24 cm (0.09 in) setback for
the CK71.
0"
16"
32"
in
80"
64"
48"
100% EAN contrast UPC
32"
16"
0"
16"
32"
0.25 mm/10 mils
48"
0.5 mm/20 mils
64"
80"
50
100
0
EX25 Minimum Reading Distances With 0.24 cm (0.09 in) Setback
Appendix A — Specifications and Default Settings
48"
64"
80"
96"
1 mm/40 mils
1.4 mm/55 mils
150
200
250
Minimum Distance
15 cm (5.91 in)
15 cm (5.91 in)
15 cm (5.91 in)
16 cm (6.30 in)
25 cm (9.84 in)
40 cm (15.75 in)
15 cm (5.91 in)
144"
160"
128"
112"
300
350
400
Maximum Distance
35 cm (13.78 in)
45 cm (17.72 in)
115 cm (45.28 in)
210 cm (82.68 in)
310 cm (122.05 in)
310 cm (122.05 in)
145 cm (57.09 in)
176"
200
160
120
80
40
0
40
80
120
160
200
cm
450
139

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ck70niCk71Ck71niCn70niCn70eCn70eni ... Show all

Table of Contents