Brother KE-430B Service Manual page 159

Electronic lockstitch bar tracker/electronic lockstitch belt loop bar tracker/electronic lockstitch pattern tracker/electronic lockstitch button sewer e series
Hide thumbs Also See for KE-430B:
Table of Contents

Advertisement

Switch
When using the inner clamping device, shunting to prevent interference
memo-15
between the inner clamping device and the needle is not carried out after the
sewing end.
memo-16
Needle cooler can be used (available by special order).
memo-17
Thread take-up device is not operated at the sewing end.
memo-18
Thread take-up device operates one stitch before the sewing end.
memo-19
For solenoid specifications, presser position errors are not detected.
memo-1A
Needle up stop position errors are not detected.
Work clamp can be moved up and down before the home position is detected.
memo-1b
(Normally the work clamp cannot be moved up and down until after the home
position has been detected.)
memo-1c
-
For pneumatic specifications, the air pressure detection switch is enabled.
memo-1d
(The air pressure sensor is a special-order option.)
Errors can be reset using the EMERGENCY STOP switch.
memo-1E
(EMERGENCY STOP switch is available as an option except for KE-434*,
435*, 484C.)
Thread is not trimmed when an emergency stop occurs during sewing.
memo-1F
(EMERGENCY STOP switch is available as an option except for KE-434*,
435*, 484C.)
<Memory switches 20 - 2F>
Switch
memo-20
-
Rotating-type thread breakage detector operates. (Device is available by
memo-21
special order.)
When thread breakage detection is operating, sensitivity is decreased at the
memo-22
sewing start. (Sensitivity during sewing is three stitches.)
[Rotating-type] 814 stitches, [Fiber-type] 510 stitches
When DIP switch A-8 is simultaneously ON, setting values changed using the
memo-23
operation panel are ignored.
memo-24
-
memo-25
-
memo-26
Enables the fiber-type thread breakage detector (when memo-21 is ON)
Test operation of pneumatic-type thread trimmer, tension release and thread
memo-27
take-up. (KE-484C)
Stores the amount of parallel movement in memory.
memo-28
(Use the memory all clear operation to clear the setting.)
Pneumatic thread wiper sensor is enabled (when memo-12=ON and
memo-29
memo-14=ON) (sensor is optional). (KE-484C)
Special emergency stop release method is used (error code E-11 is cleared by
memo-2A
pressing reset switch once and home position is cleared). (KE-484C)
memo-2b
-
-
memo-2E
memo-2F
Pneumatic thread wiper and work clamp operate together. (KE-484C)
Motion when set to ON
Motion when set to ON
KE-430B, 430C series
8. ELECTRIC MECHANISM
Initial value
Solenoid
Pneumatic
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Initial value
Solenoid
Pneumatic
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
152

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents