Using #77 Instant Activation Mode

The #77 Instant Activation Mode is used to activate outputs, bypass zones,
etc. immediately upon exiting the #77 Mode. The actions that may be
activated are relay commands, arm/disarm commands, zone bypassing
commands, and open/close access conditions.
Relay Commands
Action Code
01
Relay On
02
Relay Off
03
Relay Close for 2 seconds
Relay Close for XX minutes ✳
04
Relay Close for YY seconds ✳
05
06
Relay Group On
07
Relay Group Off
08
Relay Group Close for 2 seconds
Relay Group Close for XX minutes ✳
09
Relay Group Close for YY seconds ✳
10
✳ Check with your installer for the amount of time.
Arm/Disarm Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices
for automatic arming and disarming functions.
"During" can be used to arm or disarm the control for a specific time only.
For example, if "during" is selected with Arm-STAY, the system will
automatically Arm-STAY at the beginning of the time period and
automatically disarm at the end of the time period.
Action Code
20
Arm-STAY
21
Arm AWAY
22
Disarm
23
Force Arm STAY (Auto-bypass faulted zns)
24
Force Arm AWAY (Auto-bypass faulted zns)
25
Arm INSTANT
26
Arm MAXIMUM
Action Specifier
Relay #
Relay #
Relay #
Relay #
Relay #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Action Specifier
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
– 51 –