4.7 Configuration [1]
Default
Current port number
Value Range
Port number
Feature Guide References
None
Port Type
Selects the port type.
Notes
Each ISDN connection in a QSIG network must have a master port on one PBX and a slave port
on another PBX.
ISDN extensions can belong to an incoming call distribution group or idle extension hunting group.
In this case, an MSN can be assigned.
Default
CO
Value Range
CO: For connecting to public network
Extension: For connecting to extension
QSIG-Slave: For connecting to private network (slave port)
QSIG-Master: For connecting to private network (master port)
Feature Guide References
None
Connection
Indicates the port status (reference only).
This column offers two ways to open the screen to select the port command:
Click the desired cell in the column.
Use the arrow keys to select the desired cell in the column, and then click Command.
Default
Current status
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Programming Guide References
4.7.20 PRI Port [1-6] Port Command