Use And Care; Leak Testing - Kenmore D02 M90221 Use And Care Manual

Natural gas grill
Table of Contents

Advertisement

USE AND CARE

DANGER
• NEVER store a spare LP cylinder under or near
the appliance or in an enclosed area.
• Never fill a cylinder beyond 80% full.
• An over filled or improperly stored cylinder is a
hazard due to possible gas release from the
safety relief valve. This could cause an intense
fire with risk of property damage, serious injury
or death.
• If you see, smell or hear gas escaping,
immediately get away from the LP
cylinder/appliance and call your fire department.
WARNING
• Outdoor gas appliance is not intended to be
installed in or on a boat.
• Outdoor gas appliance is not intended to be
installed in or on an RV.
• Never attempt to attach this grill to the self-contained
LP gas system of a camper trailer or motor home.
• Do not use grill until leak-tested.
• If a leak is detected at any time, STOP and call the
fire department.
• If you cannot stop a gas leak, immediately close
gas valve and call your fire department!
10 • 466225712

Leak Testing

1. Turn all grill control knobs to OFF.
2. Be sure gas hose is tightly connected to gas
source.
3. Completely open gas source. If you hear a rushing
sound, turn gas off immediately. There is a major
leak at the connection. Correct before proceeding.
4.Brush soapy solution onto area circled below.
NOTE: Sideburner
shelf fascia not
shown for clarity.
5. If "growing" bubbles appear, there is a leak.
Close gas source immediately and tighten
connection. If leaks cannot be stopped do not
try to repair.
6.Always close gas source after performing leak
test.
Safety Tips
When grill is not in use, turn off all control
knobs and gas source.
NOTE: Your grill
may NOT be
equipped with a
sideburner.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents