Condition
Sensor test in progress
Sensors to be tested
Sensor test okay
AC power okay
AC power failure
Panel Battery voltage okay
Panel Battery voltage low
Phone communications failure
Panel receiver failure
Panel receiver interference
Protest - unable to arm due to
open sensor
Waiting for access code before
entering user programming
mode.
Alarm report aborted
Alarm report canceled
Sensors, touchpads, other devices status
Sensor closed (okay)
Restoral required sensor open
Restoral required sensor tamper
open
Bypassed sensor
RF Sensor supervisory failure
RF Sensor low battery
Hardwire sensor trouble
RF jam
DTIM trouble
DTIM phone low battery
Sensor previously in alarm
(alarm memory)
Note
If an alarm occurs, it is displayed until the panel is disarmed and will remain in the system status until checked.
Table B6: Normal Mode (Continued)
Visual Display
SENSOR TEST, followed by sensors to be
tested
TEST <Zone< sensor #> <sensor text>
ALL OK
System is OK
AC FAIL with normal display + Press Status,
AC FAIL
SYSTEM IS OK
Press Status, Low CPU Battery
Press Status, PHONE 1 (or 2) FAILURE
Press Status, Trouble + RECEIVER FAILURE
Press Status, Trouble + RECEIVER
INTERFERENCE
Protest
Open + <sensor name>
Enter Code + FOR SETTINGS
ABORTED
CANCELED
None
Press Status...
Open + <sensor name>
Press Status...
Open + Trouble + <sensor name>
Press Status...
Bypassed + <sensor name>
Press Status...
Trouble + <sensor name>
Press Status...
Low Battery + <sensor name>
Press Status...
Trouble + <sensor name>
Press Status...
Receiver Jam
Press Status...
Service Required + <sensor name>
Press Status...
Low Battery Phone Module
Press Status...
Alarm Memory + <sensor name>
Audible Response
Four beeps every minute for the last 5
minutes. One beep every second for
the last minute.
Beeps once for each transmission, up
to 8 times. Refer to Table 6: on
page 14.
High level beep when sensor heard
from received.
None.
Four short beeps every minute.
None.
Four short beeps every minute.
Four short beeps every minute.
Four short beeps every minute.
Four short beeps every minute.
Long beep followed by short beep,
then repeated.
Four short beeps every minute.
Four short beeps every minute.
Four short beeps every minute.
Four short beeps every minute.
Four short beeps every minute.
Four short beeps every minute.