Fan control
The speed of the fans is regulated according to temperature. Maximum speed
will only be achieved when switching the server on and in case of a fan test.
Sensor monitoring
Any fault in, or the removal of, a temperature sensor is detected. Should this
happen, all fans monitored by this sensor run at maximum speed to ensure the
highest possible protection of the hardware.
Voltage monitoring
When the voltage exceeds or falls below the warning levels, an alert is issued.
System Event Log (SEL)
All monitored events of the system board are signalized via the Global Error
LED or CSS LED and recorded in the System Event Log. They can be retrieved
in the iRMC S2's Web interface or via the ServerView Operations Manager.
3.8

Connectors and indicators

This section provides an overview of:
"Onboard connectors and indicators" on page 48
"External connectors and indicators" on page 55