2.45. Timesync; Synced_Clock (Id: 03500001); Failure_Communicate_With_Timeservers (Id: 03500002); Clockdrift_Too_High (Id: 03500003) - D-Link NetDefend DFL-210 Log Reference Manual

Network security firewall
Hide thumbs Also See for NetDefend DFL-210:
Table of Contents

Advertisement

2.45. TIMESYNC

2.45. TIMESYNC
These log messages refer to the TIMESYNC (Firewall time synchronization events) category.

2.45.1. synced_clock (ID: 03500001)

Default Severity
Log Message
Explanation
Gateway Action
Recommended Action
Revision
Parameters
2.45.2. failure_communicate_with_timeservers (ID:
03500002)
Default Severity
Log Message
Explanation
Gateway Action
Recommended Action
Revision

2.45.3. clockdrift_too_high (ID: 03500003)

Default Severity
Log Message
Explanation
Gateway Action
Recommended Action
NOTICE
The clock at <oldtime>, was off by <clockdrift> second(s) and
synchronized with <timeserver> to <newtime>
The clock has been synchronized with the time server.
None
None.
2
oldtime
newtime
clockdrift
timeserver
WARNING
Communication with the timeserver(s) failed. Clock not updated.
The unit failed to establish a connection with the time sync server. The
clock has not been updated.
clock_not_synced
Verify that the time sync server is running.
1
WARNING
According to the timeserver the clock has drifted <clockdrift>
seconds(s) which is NOT in the allowed correction interval
(+/-<interval> seconds)
The clock has drifted so much that it is not within the allowed +/-
correction interval. The clock will not be updated.
clock_not_synced
If the correction interval is too narrow, it can be changed in the
Advanced Settings section.
443
Chapter 2. Log Message Reference

Advertisement

Table of Contents
loading

Table of Contents