Error Code
Message Information
Details
Action
PWR1001
Message
LCD Message
Details
Action
PWR1002
Message
Details
Action
PWR1003
Message
Details
Action
PWR1004
Message
Details
Action
PWR1005
Message
Details
122
The current power operational mode is non-redundant because of a
power supply exception, a power supply inventory change, or a
system power inventory change.
Check the event log for power supply failures. Review system
configuration and power consumption.
The system performance was degraded.
System performance degraded. Check PSUs and system
configuration.
To avoid shutdown, system performance has been degraded.
Review system configuration and system logs for thermal or
environmental failures and warnings.
The system performance degraded because of thermal protection.
To avoid shutdown, system performance has been degraded.
Review system configuration and system logs for thermal or
environmental failures and warnings.
The system performance degraded because cooling capacity has
changed.
The current power supply configuration does not meet the platform
requirements to enable redundancy. If a power supply fails the
system may shutdown.
If unintended, review system configuration and power consumption
and install power supplies accordingly. Check power supply status
for failures.
The system performance degraded because power capacity has
changed.
The system may power down or operate in a performance degraded
state.
Check the event log for power supply failures. Review system
configuration and power consumption and upgrade or install power
supplies accordingly.
The system performance degraded because the user-defined power
capacity has changed.
The user-defined power settings have affected system operation.