Needle Zigzag Home Position Adjustment Procedure - Brother Z-8550A Service Manual

Electronic direct drive zigzag lock stitcher with thread trimmer
Hide thumbs Also See for Z-8550A:
Table of Contents

Advertisement

3-8. Needle zigzag home position adjustment procedure

OPERATION PROCEDURE
1
While pressing the [zigzag width/zigzag reference line position] key on the operation panel, turn on the power switch
(1).
2
Move the needle bar to the needle up stop position, and then press and hold the RESET key for 2 seconds or more.
3
Use the home position checking tool, and press the [
needle is at the home position.
4
Move the needle bar to the needle up stop position, and then press the RESET key.
5
Repeat steps 3 and 4 to set the needle to the home position.
6
Press the TEST key.
NOTE:
If the TEST key is pressed while [orG] is flashing, [Err 202] will appear.
Press the TEST key once more to exit adjustment mode. Repeat the procedure from step 3.
Home position detection will be carried out, and then the needle bar
will stop at the currently-recorded position.
After detection is complete, the [orG] display will stop flashing and
illuminate steadily.
* If [Err 200] appears, it indicates that there is a problem with the
needle zigzag motor home position.
* If [UP] appears, turn the pulley by hand to move the needle bar to
the needle up stop position, and then press the RESET key once
more. Home position detection will be carried out.
/
] keys to change the offset value (-50 - 50) so that the
The needle bar will move in accordance with the setting value.
When the setting has been changed, the [orG] display will change
from illuminated to flashing.
Home position detection will be carried out.
After detection is complete, the [orG] display will stop flashing and
illuminate steadily.
* If [UP] appears, turn the pulley by hand to move the needle bar to
the needle up stop position, and then press the RESET key once
more. Home position detection will be carried out.
The [TEST] display and the [zigzag width/zigzag reference line
position] indicator will switch off.
The setting will be written to the machine head memory and
adjustment mode will be exited.
Z-8550A, 8560A
3. FUNCTION SETTINGS
The offset value will be displayed.
(Initial setting is "0")
0185B
0186B
0187B
0186B
0183B
22