Power supplies
Symptom
Battery cannot be
charged.
Battery weakens fast. Are you using the camcorder where the temperature is
The CHARGE
indicator on AC
adapter/charger is
blinking.
140
Cause and Correction
Is the DC power cord connected to the AC adapter/
charger? Unplug it.
Is the battery abnormally hot?
Remove the battery, leave it for a while to cool down, then
charge it.
Is the ambient temperature too low or too high?
Charge the battery at 50 – 86ºF (10 – 30ºC).
Has the battery been unused for a long time?
Remove the battery, and then reattach it.
If the battery does not charge after trying all of the above,
it may be dead. Purchase a new battery.
low?
A fully charged battery (DZ-BP14S/DZ-BP14SW) may
be discharged sooner than usual at low temperatures.
Keep extra batteries on hand.
Battery may be dead.
The performance of the battery will deteriorate if it is
used for an extended period of time or frequently.
Purchase a new battery.
Is the ambient temperature too low or too high?
Charge the battery at 50 – 86ºF (10 – 30ºC).
If the battery is completely drained (for example, if it has
not been used for over a year), it may take longer to begin
charging. Continue charging: after awhile, the battery
may recover enough voltage to begin charging normally
and the CHARGE indicator will light.