For example if the 16 Mbyte SIMM (sample data RAM)
included with the EXB-SMPL option (sold separately) is
installed in slot 1 and you install 32 Mbytes in slot 2,
you will be able to select "Bank (RAM Bank)" 1 (16
Mbyte), 3 (16 Mbyte), and 4 (16 Mbyte). Each bank is a
16 Mbyte unit. (If you install a 32 Mbyte SIMM in slot 1
and slot 2, all banks can be selected, and the total capac-
ity will be 64 Mbytes.)
Mode (Sample Mode)
Select s the channel(s) to be sampled, to specify whether a
mono or a stereo sample will be recorded.
Depending on the "Input1, Input2" (1.1–3a) settings, the
external source from the AUDIO INPUT 1 and 2 jacks will be
sent, either as direct sound without being routed through an
effect, or as effect-processed sound routed through an inser-
tion effect, to the L/R bus and sampled from the internal L
and R channels.
L-Mono: The sound of the internal L channel will be sam-
pled in mono.
R-Mono: The sound of the internal R channel will be sam-
pled in mono.
Stereo: The sound of the internal L and R channels will be
sampled in stereo. When you sample in stereo, a stereo mul-
tisample or sample will be created.
Example 1:
Sampling a monaural source connected to AUDIO INPUT 1
without applying internal effects
Input1 "Lvl (Level)"
(1.1–3a)
Input1 "Pan"
(1.1–3a)
Input1 "BUS
(1.1–3a)
(BUS(IFX)Select)"
"Recording Level"
(1.1–2c, 1.1–3e)
"Mode (Sample Mode)"
(1.1–2a)
Example 2:
A monaural source connected to AUDIO INPUT 1 routed
through the internal insertion effect IFX 52: Rev Hall, and
sampled in stereo
Input1 "Lvl (Level)"
(1.1–3a)
Input1 "Pan"
(1.1–3a)
Input1 "BUS
(1.1–3a)
(BUS(IFX)Select)"
IFX
(7.1)
"Recording Level"
(1.1–2c, 1.1–3e)
"Mode (Sample Mode)"
(1.1–2a)
Example 3:
A stereo source connected to AUDIO INPUT 1 and 2, and
sampling without applying internal effects
Input1 "Lvl (Level)"
(1.1–3a)
Input1 "Pan"
(1.1–3a)
Input1 "BUS
(1.1–3a)
(BUS(IFX)Select)"
Input2 "Lvl (Level)"
(1.1–3a)
Input2 "Pan"
(1.1–3a)
Input2 "BUS
(1.1–3a)
(BUS(IFX)Select)"
"Recording Level"
(1.1–2c, 1.1–3e)
"Mode (Sample Mode)"
(1.1–2a)
[L-Mono, R-Mono, Stereo]
127
L000
L/R
as appropriate
L-Mono
127
C064
IFX
select 52: Reverb Hall
and make settings
as appropriate
Stereo
127
L000
L/R
127
R127
L/R
as appropriate
Stereo
Example 4:
A stereo source connected to AUDIO INPUT 1 and 2, routed
through internal insertion effect IFX 08: St.Graphic 7EQ, and
sampled in stereo
Input1 "Lvl (Level)"
(1.1–3a)
Input1 "Pan"
(1.1–3a)
Input1 "BUS
(1.1–3a)
(BUS(IFX)Select)"
Input2 "Lvl (Level)"
(1.1–3a)
Input2 "Pan"
(1.1–3a)
Input2 "BUS
(1.1–3a)
(BUS(IFX)Select)"
IFX
(7.1)
"Recording Level"
(1.1–2c, 1.1–3e)
"Mode (Sample Mode)"
(1.1–2a)
When you finish recording a stereo sample, you may
hear a slight noise. This does not affect the audio data
that has been sampled.
1.1–2b: REC Setup
Mode (REC Mode)
Select s the method by which sampling will be started.
Manual: Sampling will start when you press the [START/
STOP] key from the sampling standby condition.
1 Press the [REC/WRITE] key to enter sampling standby
mode.
2 Use the "Recording Level" (1.1–2c, 1.1–3e) slider to
adjust the sampling level.
Be careful of changes in the monitoring volume level
( ☞ "Recording Level").
3 Sampling will begin when you press the [START/STOP]
key. If you use the "Count Down" function, pressing the
[START/STOP] key will cause sampling to begin after
the metronome sounds a count-down.
4 To stop sampling, press the [START/STOP] key once
again. Sampling will end automatically if you continue
sampling to the end of the "Time (Sample Time)" (1.1–
2a).
Auto: Sampling will begin automatically when the input
level exceeds the "Threshold" setting.
1 Perform steps 1 and 2 described above.
2 Adjust the "Threshold" setting. The black triangles at
both sides of the "Recording Level" level bar display will
indicate the "Threshold" level. Normally, this should be
set as low as possible without allowing noise to trigger
sampling.
3 Press the [START/STOP] key.
Sampling will automatically begin when the input level
exceeds the "Threshold" setting.
4 When you are finished sampling, perform step 4 of the
Manual procedure.
Threshold
When performing auto sampling ("Mode (REC Mode)"
Auto), this sets the level at which sampling will begin
( ☞ "Mode (REC Mode)" Auto, step 2 ).
This will not be displayed if "Mode (REC Mode)" is set
to Manual.
127
L000
IFX
127
R127
IFX
select 08: St.Graphic
7EQ and make settings
as appropriate
Stereo
[Manual, Auto]
[–63dB...0dB]
93