TESTING
❒ Turn on the circuit breaker and light
switch.
NOTE: Sensor has a 1
period before it will detect motion.
When first turned on or when switch-
ing modes wait 1
❒ Switch the on-time to TEST position and
D
B
switch to the OFF position.
®
ual
rite
TEST 1 5 10 MIN
ON-TIME
Avoid locations that will cause
the control to "see":
• Objects that change temperature rapidly,
such as heating vents and air condition-
ers. These heat sources could cause false
triggering.
• Areas where pets or traffic may trigger
the control.
• Nearby large, light-colored objects
reflecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.
6 Ft.
(1.8 m)
Maximum
Range
595-5770-05
/
minute warm up
1
2
/
minutes.
1
2
OFF 3 6 DUSK TO
HOUR DAWN
30 Feet
(9.1 m)
Maximum
Coverage Angle
The detector is less sensitive to motion directly
towards it and more sensitive to across motion.
Motion
Least Sensitive
❒ Walk through the coverage area noting
where you are when the lights turn on.
❒ If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity
may cause false triggering in some
installations.
❒ Set the amount of TIME you want the
light to stay on after motion is detected.
(1, 5, or 10 minutes).
TEST 1 5 10 MIN
❒ Set the amount of time after dusk you
want the lights on accent level.

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 30 ft. (9.1 m)
180°
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . . Up to 100 Watt Maximum
Sensor Capacity . . . . . Up to 360 Watt (3.0 A.)
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO, and
Time Delay . . . . . . . . . 1, 5, 10 minutes
D
B
®
ual
rite
The Hampton Bay Lighting Company reserves
the right to discontinue products and to change
specifications at any time without incurring any
obligation to incorporate new features in products
previously sold.
5
Sensor
Most Sensitive
OFF 3 6 DUSK TO
[varies with surrounding
temperature].
Incandescent
Maximum
MANUAL MODE
timer . . . . . Off, 3, 6 hrs, to dawn
Motion
HOUR DAWN