Advertisement

CAT System Computer Control
Parameter Bytes
Command
or Key
1st
2rd
TUNER
Tuner Start
Dual Operation
[ RPT ]
u
[ A
B ]
Set SUB
VFO-B
F1
F2
Operating Freq.
BANDWIDTH
2ud & 3rd IF
X1
Filter Selection
MEM. Channel
Scan Skip
Step VFO-A
UP/DOWN
CTCSS
Encoder
E
Tone Frequency
Select
Read Meter &
Panel Controls
Repeater
X1
X2
Offset
page 96
Opcode Command Chart (3)
Opcode
3rd
4th
5th
T
81H
82H
D
83H
R
84H
85H
F3
F4
8AH
X4
8CH
S
X
8DH
T
8EH
E
E
E
90H
F7H
X3
X4
F9H
Parameter Description
Switch Antenna Tuner ON ( T = 01H ) or OFF ( T = 00H )
Start Antenna Tuning
Switch Dual Receive ON ( D = 01H ) or OFF ( D = 00H )
Switch Simplex Operation ( R = 00H ), Minus Shift ( R = 01H ),
or Plus Shift ( R = 02H ) for Repeater Operation
Copy Data Display in VFO-A or VFO-B.
Enter new operating frequency in F1 ~ F4, in BCD format:
see text for example.
Select filter bandwidth for selected IF ( see below ) :
8.2 MHz
455 kHz
THRU: X4 = 09 6.0 kHz: X4 = 84 Both: X1 = 00
2.4 kHz: X4 = 002.4 kHz: X4 = 80
2.0 kHz: X4 = 012.0 kHz: X4 = 81
500 Hz: X4 = 02 500 Hz: X4 = 82
500 Hz: X4 = 03 500 Hz: X4 = 83
Tag memory channels 1 thruogh 99 ( X = 01H ~ 6CH ) , to be
skipped ( S = 01H ) or included ( S = 00H ) while scanning.
Step frequency of VFO-A UP ( T = 00H ) or DOWN ( T = 01H )
Select one of 33 CTCSS subaudible tones
where E = 00H ~ 20H
E = 00H67.0 Hz
E = 0BH118.8 Hz
E = 01H71.9 Hz
E = 0CH123.0 Hz
E = 02H77.0 Hz
E = 0DH127.3 Hz
E = 03H82.5 Hz
E = 0EH131.8 Hz
E = 04H88.5 Hz
E = 0FH136.5 Hz
E = 05H94.8 Hz
E = 10H141.3 Hz
E = 06H100.0 Hz
E = 11H146.2 Hz
E = 07H103.5 Hz
E = 12H151.4 Hz
E = 08H107.2 Hz
E = 13H156.7 Hz
E = 09H110.9 Hz
E = 14H162.2 Hz
E = 0AH114.8 Hz E = 15H167.9 Hz
Instruct radio to return digitized indications of various meter
level readings and front panel control settings (4 repeated
bytes, and F7H) selected by:
M = 00HMain S-Meter
M = 01HSub S-Meter
M = 80H PO Meter
M = 81HALC Meter
M = 83HIC Meter
M = 84HVCC Meter
M = 85HSWR Meter
M = 86HMIC Meter
Set offset for RPT shift, valid values are
0 ~ 500 kHz in 1-kHz step. Use BCD format for X2 ~ X4.
X1 is 10's & 100's of Hz
X3 is must be 00H, 01H, or 02HX4 is must be 00H
MARK-V FT-1000MP Operating Manual
VFO
VFO-A: X1 = 01
VFO-B: X1 = 02
E = 16H173.8 Hz
E = 17H179.9 Hz
E = 18H186.2 Hz
E = 19H192.8 Hz
E = 1AH203.5 Hz
E = 1BH210.7 Hz
E = 1CH218.1 Hz
E = 1DH225.7 Hz
E = 1EH233.6 Hz
E = 1FH241.8 Hz
E = 20H250.3 Hz
M = 87HTUN Meter
M = F0HShuttle Jog Dial
M = F1HCW Pitch Setting
M = F2HRemote Control A/D Level
M = F3HSHIFT Setting
M = F4HWIDTH Setting
M = F5HEDSP Contour Selection
M = F6HEDSP NR Selection
X2 is 1's & 10's of kHz

Advertisement

Comments to this Manuals

Symbols: 0
Latest comments: