Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
BROIL ELEMENT
Refer to page 4-8 for the procedure for servic-
ing the broil element.
1. Unplug range or disconnect power.
2. Disconnect one of the wires from the broil
element terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the broil
element terminals. The meter should indicate
between 14 and 16 Ω.
WARNING
Electrical Shock Hazard
COOLING FAN MOTOR
Refer to page 4-7 for the procedure for servic-
ing the broil element.
1. Unplug range or disconnect power.
2. Disconnect one of the wires from the cooling
fan motor terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the cool-
ing fan motor terminals. The meter should
indicate between 14 and 16 Ω.
5-4