Craftsman 919.167370 Owner's Manual page 17

Permanently lubricated tank mounted
Hide thumbs Also See for 919.167370:
Table of Contents

Advertisement

Available languages

Available languages

To Replace Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug unit.
3.
Using an adjustable wrench or
specified wrench remove the
gauges (7/16" wrench), quick
connect (13/16" wrench), and
safety valve (9/16" wrench) from
the regulator manifold.
Gauges
Safety Valve
4.
Remove the hose by removing
the hose clamp. NOTE: The hose
clamp is not reusable. You must
purchase a new hose clamp, see
the Parts List Manual or purchase
a standard hose clamp at a local
hardware store.
Quick
Connect
Regulator
Manifold
17 - ENG
Hose Clamp
5.
Using an adjustable wrench or
5/8" wrench remove the regulator
manifold.
6.
Apply pipe sealant to new
regulator manifold and assemble,
tighten with wrench.
7.
Reapply pipe sealant to gauges,
quick connect, and safety valve.
8.
Reassemble all components in
reverse order of removal. Make
sure to orient gauges to read
correctly and use wrenches to
tighten all components.
Regulator
Manifold
N000317