Craftsman 919.167281 Owner's Manual page 22

Permanently lubricated single stage portable air compressor
Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
Regulator will
not shut off air
outlet.
Motor will not
run.
A17893
CAUSE
Damaged regulator.
Motor overload protection
switch has tripped.
Tank pressure exceeds pres-
sure switch "cut-in" pressure.
Extension cord is wrong
length or gauge.
Check valve stuck open.
Loose electrical connections. Check wiring connection
Possible defective motor or
starting capacitor.
Paint spray on internal motor
parts.
Pressure release valve on
pressure switch has not un-
loaded head pressure.
Fuse blown, circuit breaker
tripped.
Replace.
Let motor cool off and over-
load switch will automatically
reset.
Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.
Check for proper gauge wire
and cord length.
Remove and clean, or re-
place.
inside pressure switch and
terminal box area.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician. Do not
operate the compressor in
the paint spray area. See
flammable vapor warning.
Bleed the line by pushing the
lever on the pressure switch
to the "OFF" position; if the
valve does not open, replace
switch.
1.
2.
3.
4.
22- ENG
CORRECTION
Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a
fuse or circuit breaker
with higher rating than
that specified for your
particular branch circuit.
Check for proper fuse.
You should use a time
delay fuse.
Check for low voltage
conditions and/or proper
extension cord.
Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

919.167280

Table of Contents