Fujitsu Siemens Computers D2352 Tehnical Manual
Fujitsu Siemens Computers D2352 Tehnical Manual

Fujitsu Siemens Computers D2352 Tehnical Manual

System board d2352 for tx600 s3/rx600 s3

Advertisement

Quick Links

PRIMERGY
System Board D2352
for TX600 S3/RX600 S3
Technical manual
Gottfried Staubach
Fujitsu Siemens Computers GmbH Paderborn
33094 Paderborn
e-mail: email: manuals@fujitsu-siemens.com
Tel.: 05251 / 14888-19
Fax: (++49) 700 / 372 00001
D2352 (TX600 S3/RX600 S3)
Sprachen: En
Edition December 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D2352 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fujitsu Siemens Computers D2352

  • Page 1 PRIMERGY System Board D2352 for TX600 S3/RX600 S3 Technical manual Gottfried Staubach Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: 05251 / 14888-19 Fax: (++49) 700 / 372 00001 D2352 (TX600 S3/RX600 S3) Sprachen: En Edition December 2006...
  • Page 2 Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2006 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Replacing the lithium battery ....23 Abbreviations ....... 25 D2352 (TX600 S3/RX600 S3)
  • Page 5: Introduction

    Introduction This technical manual describes the system board D2352, which can be ® equipped with up to four Intel processors. Further information about drivers is provided in the readme files on the supplied ServerSupport or ServerStart CDs. You will find further information in the manual "D2352 Setup Utility".
  • Page 7: Important Notes

    Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. D2352 (TX600 S3/RX600 S3)
  • Page 8 All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant: Cd Cadmium Hg Mercury Pb Lead D2352 (TX600 S3/RX600 S3)
  • Page 9 Use a grounding cable designed for this purpose to connect yourself to the system unit as you install/deinstall the board. Place all components on a static-safe base. You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). D2352 (TX600 S3/RX600 S3)
  • Page 10: Ce Certificate

    Never use sharp objects (screwdrivers) for leverage. CE Certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC "Electromagnetic compatibility". Compliance was tested in a typical PRIMERGY configuration. D2352 (TX600 S3/RX600 S3)
  • Page 11: Environment Protection

    Environment Protection Environment Protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu Siemens Computers standard for “environmentally friendly product design and devel- opment”. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of disassembly and recycling have been taken into account.
  • Page 12 – Meaning of the symbol "Crossed out rubbish bin on wheels" Electrical (electronic) devices which are marked with one of the following symbols may not be disposed of with household refuse in accordance with the EU directive. Figure 2: Symbols for electrical (electronic) devices D2352 (TX600 S3/RX600 S3)
  • Page 13 Local contacts For details on take-back and reuse of devices and consumables within Europe, contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling center in Paderborn: Fujitsu Siemens Computers...
  • Page 15: Features

    – Two 100 MHz, 64-bit PCI-X slots (not hot-plug) ® LSI Logic 53C1030 LVD SCSI controller: – Dual independent U320 SCSI interfaces – 64-bit PCI-X 100 Mhz interface ® Integrated ATI Technologies Inc Radeon 7000M with 16 MB embedded SDRAM D2352 (TX600 S3/RX600 S3)
  • Page 16 1x RJ45 LAN port (presently not used, reserved for future development) BIOS features ® – Intel Platform Innovation Framework EFI BIOS – MultiProcessor Specification 1.4 – Server Hardware Design Guide 3.0 – WfM 2.0 – IPMI V1.5 – ACPI 1.0b support D2352 (TX600 S3/RX600 S3)
  • Page 17 – boot possible from: – CD/DVD-ROM – USB drive – LAN – hard disk – console redirection support – OEM logo – CPU, Memory disable – memory mirroring/RAID/spare support Environmental protection Battery in holder Form factor 16.4“ x 18.3“ D2352 (TX600 S3/RX600 S3)
  • Page 18: Main Memory

    – Install the memory modules in pairs. All DIMMs in a pair must be of the same type and size. – The module capacity between pairs can differ: pair 2A/2B can be populated with two 1 Gbyte modules and pair 1A/1B with two 2 Gbyte modules. D2352 (TX600 S3/RX600 S3)
  • Page 19: Pci Bus

    1250 Mbyte/s PCI-Express x4 slot 800 Mbyte/s PCI-X bus slot (100MHz) 800 Mbyte/s PCI-X bus slot (100MHz) Assignment of the PCI interrupts The PCI interrupts are assigned automatically by the BIOS and no further settings are possible. D2352 (TX600 S3/RX600 S3)
  • Page 20: Screen Resolution

    The temperature and system monitoring are controlled by an onboard controller. The following functions are supported: Temperature monitoring Measurement of the processor temperature, measurement of the ambient temperature by a temperature sensor on the LED board. D2352 (TX600 S3/RX600 S3)
  • Page 21 When voltage exceeds warning level high or falls below warning level low an alert will be generated. System Event Log (SEL) All monitored events of the system board are recorded in the System Event Log. They could be retrieved after a system reboot via ServerView. D2352 (TX600 S3/RX600 S3)
  • Page 22: Connectors And Jumpers

    Connectors and jumpers Features Connectors and jumpers 18 17 16 15 Figure 6: Schematic overview of the system board D2352 1 = J8C2 (jumper) 12 = Processor socket 4 2 = Memory board connector B 13 = Processor socket 3...
  • Page 23 J8C2 = BMC Reset Figure 7: Jumper default settings J4A1 (26) - Password Clear Password enabled Password disabled/cleared J4A2 (27) - BIOS Write Protect BIOS unprotected BIOS write protected J4A3 (28) - BIOS Recovery Normal boot BIOS recovery D2352 (TX600 S3/RX600 S3)
  • Page 24: External Connectors

    This LAN controller supports the transfer rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller supports WOL function through Magic Packet™. It is also possible to boot a device without its own boot hard disk via LAN. Here Intel PXE is supported. D2352 (TX600 S3/RX600 S3)
  • Page 25: Romb

    IOP332 I/O processor becomes a RAID5 (RAID 0, 1, 5, 10, 50 ) controller by using a RAID activation key and a cache module. The following figure shows the installed components. Figure 10: RoMB; 1=RAID activation key, 2=cache module D2352 (TX600 S3/RX600 S3)
  • Page 27: Replacing The Lithium Battery

    Ê Press the locking spring into direction of of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Ê Reinstall the memory board in connector A. D2352 (TX600 S3/RX600 S3)
  • Page 29: Abbreviations

    Advanced Configuration and Power management Interface ANSI American National Standards Institute ASR&R Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Central Processing Unit D2352 (TX600 S3/RX600 S3)
  • Page 30 Dynamic Random Access Memory Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory Extensible Firmware Interface Elektrostatisch gefährdete Bauteile Electromagnetic interference EMRL Embedded RAID Logic Elektromagnetische Verträglichkeit (electromagnetic compatibility) EPROM Erasable Programmable Read Only Memory ElectroStatic Discharge D2352 (TX600 S3/RX600 S3)
  • Page 31 Front Side Bus In Circuit Emulation Integrated (intelligent) Drive Electronics International Electrotechnical Commission Integrated Mirroring Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface International Organisation for Standardisation Local Area Network D2352 (TX600 S3/RX600 S3)
  • Page 32 Original Equipment Manufacturer OHCI Open Host Controller Interface Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Power Distribution Board Programmable Logic Device PS(U) Power Supply (Unit) Pulse Wide Modulation Preboot eXecution Environment D2352 (TX600 S3/RX600 S3)
  • Page 33 Real Time Clock SCSI Small Computer Systems Interface SATA Serial Advanced Technology Attachment SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory System Event Log SHDG Server Hardware Design Guide System Management Bus Server Management Mode D2352 (TX600 S3/RX600 S3)
  • Page 34 Symmetrical Multi Processing UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module WEEE Waste from Electric and Electronic Equipment (EU Directive) Wired for Management Wake up On LAN D2352 (TX600 S3/RX600 S3)
  • Page 35 Comments Fujitsu Siemens Computers GmbH User Documentation 33094 Paderborn Suggestions Germany Corrections Fax: (++49) 700 / 372 00001 e-mail: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on System Board D2352 for TX600 S3/RX600 S3 D2352 (TX600 S3/RX600 S3)
  • Page 37 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Table of Contents