GAS SUPPLY REQUIREMENTS
1. Installation MUST conform with local codes, or in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1 (latest edition) or in Canada, the current
CAN/CGA B149.
2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect
your dryer to the gas supply line. The tubing MUST be
constructed of stainless steel or plastic-coated brass.
4. The gas supply fine MUST have an individual shutoff valve.
5. A 1/8 inch (0.32 cm) N.RT. plugged tapping, accessible
for test gage connection, MUST be installed immediately
upstream of the gas supply connection to the dryer,
6. The dryer and its individual
shutoff
valve MUST be
disconnected from the gas supply piping system during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.45 kPa).
7. The dryer MUST be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at
test pressures equal to or less than t/2 psig (3.45 kPa).
LOCATION OF YOUR LAUNDRY CENTER
DO NOT INSTALL YOUR LAUNDRY CENTER:
1. In an area exposed to dripping water or outside weather
conditions.
2. In an area where it will come in contact with curtains or
drapes.
3. On carpet. Floor MUST be solid with a maximum slope of
1 inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
I. A laundry center installed in a bedroom, bathroom, recess
or closet, MUST be exhausted outdoors.
2. NO other fuel burning appliance shall be installed in the
same closet as the Gas laundry center.
3 Your taundry center needs the space around it for proper
ve_
[liL]tlo[
DO NOT INSTALL YOUR LAUNDRY
CENTER IN A
CLOSET WITH A SOLID DOOR.
4. A minimum of 120 square inches (774.2 square cm) of
opening, equally divided at the top and bottom of the
door, is required.
Air openings
are required
to be
unobstructed when a door is installed. A touvered door
with equivalent air openings for the full length of the door
is acceptable.
6_0 SQ, IN.
(387,1 5Q. CM)
T
0
(387,1
SQ, CM)
CLOSET DOOR
.
4
The following
illustrations
show minimum
clearance
dimensions
for proper operation
in a recess or closet
installation.
0 IN.
(o CM)
!_
_
THI
I[
i I
WASHER
T
SIDE
VIEW
MOBILE
HOME
INSTALLATION
1. Dryer MUST be exhausted outside (outdoors, not beneath
the mobite home) using metal ducting that will not support
combustion. Metal ducting must be 4 inches (10.16 cm)in
diameter with not obstructions. Rigid metal duct is preferred.
2. If dryer is exhausted through the floor and area beneath
the mobile home is enclosed, the exhaust system MUST
terminate
outside the enclosure with the termination
securely fastened to the mobile home structure.
3. Refer to page 3 for other important venting requirements.
F
7
4. When installing a gas dryer into a mobile home, a provision
must be made for outside make up air. This provision is to
be not less than twice the area of the dryer exhaust outlet.
5. Installation MUST conform to current Manufactured Home
Construction & Safety Standard (which isa Federal Regulation
Title 24 CFR-Part 32-80) or when such standard is not
applicable, with American National Standard for Mobile
Homes. tn Canada, the CSA Z240 is applicable.
The laundry center is designed under ANSI Z
21.5.1 for HOME USE only.