Pre-Installation Requirements; Electrical Requirements; Water Supply Requirements; Drain Requirements - Frigidaire FLEB43RGS0 Installation Instructions Manual

Full size laundry center gas & electric
Table of Contents

Advertisement

PRE-INSTALLATION
REQUIREMENTS
Tools and Materials Required for Installation:
1. Phillips head screwdriver.
2. Channel-lock adjustable pliers.
3. Carpenter's level.
4. Flat or straight blade screwdriven
5. Duct tape.
6. Rigid or flexible metal 4 inch (10.16 cm) duct.
7. Vent hood.
8. Pipe thread sealer (Gas).
9. Ratchet with 3/8 inch (0.96 cm) socket.
ELECTRICAL REQUIREMENTS
ELECTRICLaundry Center
Circuit- Individual 30 amp branch circuit fused with 30 amp
minimum time delay fuses or circuit breakers.
POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60
Hz, Alternating Current.
POWER SUPPLYCORD KIT-The laundry center MUST employ
a 3-condutor power supply cord NEMA 10-30 type SRDTrated
at 240 volt AC minimum, 30 amp, with 3 open end spade lug
connectors with upturned ends or closed loop connector OR a
4-condutor power supply cord NEMA 14-30 type SRDTor ST
(as required) rated at 240 volt AC minimum, 30 amp, with 4
open end spade lug connectors with upturned ends or closed
loop connectors and marked for usewith clothes dryers. If being
installed in a manufactured (mobile) home, the laundrycenter
MUST employ a 4-condutor power supply cord NEMA 14- 30
type SRDTor ST (as required) rated at 240 volt AC minimum,
30 amp, with 4 open end spade lug connectors with upturned
ends or closed loop connectors and marked for use with clothes
dryers. See ELECTRICAL CONNECTIONS. (Canada - 4-wire
power supply cord is installed on laundry center.)
OUTLET RECEPTACLE- NEMA 10-30R (3-wire) receptacle or
NEMA 14- 30R (4-wire) receptacle to be located so the power
supply cord is accessible when the laundry center is in an
installed position.
POWER SUPPLY CORD -The gas laundry center is equipped
with a 120 volt 3-wire power cord.
NOTE: Do not under
any circumstances
remove grounding
prong from plug.
\
Grounding Prong
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42 inches
(106.68 cm) of your laundry center's water inlet. The faucets
MUST be 3/4 inch (1.9 cm) garden hose type so inlet hoses can
be connected. Water pressure MUST be between 10 and 120
pounds per square inch (maximum unbalance pressure, hot vs.
cold, 10 psi). Your water department can advise you of your
water pressure. The hot water temperature should be about
140 degrees E
DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 gals. per minute.
2. A standpipe diameter of 1-1/4 inches (3.18 cm) minimum.
3. The standpipe height above the floor should be:
Minimum height: 33 inches (83.82 cm)
Maximum height: 96 inches (244 cm)
T
96"Max.
(244 cm)
-"T"-
33" Min.
__L
NEMA 10-30R
NEMA 14-30R
I
GAS Laundry Center
I
CIRCUIT -individual 15 amp branch circuit fused with a 15 amp
maximum time delay fuse or circuit breaker.
NOTE:For installations requiring a longer drain hose, have a
qualified technician install a longer hose PIN 131461201,
available from an authorized parts distributor. For drain
systems in the floor, install a siphon break kit, available
from your local hardware store.
POWER SUPPLY -3 wire, 120 volt single phase, 60 Hz,
Alternating Current,
2