Drain System; Electrical Requirements - Maytag BRAVOS Use & Care Manual

Automatic washer
Hide thumbs Also See for BRAVOS:
Table of Contents

Advertisement

Available languages

Available languages

Drain System

The washer can be installed using the standpipe drain system (floor or wall), the laundry tub
drain system, or the floor drain system. Select the drain hose installation method you need.
See "Tools and Parts."
Standpipe drain system—wall or floor (views A & B)
The standpipe drain requires a minimum diameter standpipe of 2" (5.0 cm). The minimum
carry-away capacity can be no less than 17 gal. (64 L) per minute. A 2" (5.0 cm) diameter to
1" (2.5 cm) diameter standpipe adapter kit is available. See "Tools and Parts."
The top of the standpipe must be at least 39" (99.0 cm) high and no higher than
96" (244.0 cm) from the bottom of the washer.
A
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be
at least 39" (99.0 cm) above the floor and no higher than 96" (244.0 cm) from the bottom of
the washer.
floor drain system (view D)
The floor drain system requires a siphon break that may be purchased separately. See "Tools
and Parts."
The siphon break must be a minimum of 28" (71.0 cm) from the bottom of the washer.
Additional hoses might be needed.
C
6
39"
(99 cm)
B
28"
(71 cm)
39"
(99 cm)
D

Electrical Requirements

A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-
delay fuse or circuit breaker is recommended. It is recommended that a separate circuit
serving only this appliance be provided.
This washer is equipped with a power supply cord having a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be plugged into a mating, grounded
3 prong outlet, grounded in accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and obligation of the customer to
have the properly grounded outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is recommended that a qualified
electrician determine that the ground path is adequate.
Do not ground to a gas pipe.