10. Connect the appropriate power cable
hard disk drive.
Figure 69. Connecting cables to the rear of the non-hot-swap hard disk drive
The following table provides information about the recommended power connector and system
board SATA connector for the non-hot-swap hard disk drive installed in each drive bay. See "Server
components" on page 25 and "System board components" on page 42 for the location information
about the hard disk drive bays and SATA connectors on the system board.
Non-hot-swap hard disk drive
Installed in bay 0
Installed in bay 1
Installed in bay 2
Installed in bay 3
11. Connect the other end of the SATA signal cable to the appropriate SATA connector on the system board.
See "System board components" on page 42.
12. Reinstall the front system fan 1. See "Replacing the front system fan" on page 149.
132
ThinkServer User Guide
1
and the SATA signal cable
Power connector
P9 power connector
P10 power connector
P7 power connector
P8 power connector
2
to the rear of the non-hot-swap
System board SATA connector
SATA connector 0
SATA connector 1
SATA connector 2
SATA connector 3