Gas Connection - Zanussi ZCM 6605 Instruction Booklet

Mixed fuel cooker zcm 6605
Table of Contents

Advertisement

Gas connection

The connection of the cooker to the gas bottle or to the
mains should only be carried out after the unit has been
regulated for use with the type of gas which will be
supplied. Be sure that you are going to connect the unit
to the same kind of gas written on the plate. For safe
operation, minimum consumption and longer duration of
the unit, make sure that the pressure of supply is equal
to the value indicated in the Technical Data section.
IMPORTANT
Once installation is complete, check the perfect
seal of every pipe fitting, using a soapy solution,
never a flame.
Rigid connection
For a greater safety, it is advisable to make a rigid
connection to the gas installation. The coupling to the
unit is of Gc 1/2 type. If the connection pipe is in metal,
an insulated adaptor must be interposed between the
coupling and the tube.
Connection with flexible pipe
Use a flexible gas pipe, according to the characteristics
indicated by the existing regulations. The pipe should be
well fitted and fixed by means of a clamp. To reach the
supply connection, the pipe should be passed behind
the cooker as shown in the diagram. We bring to your
attention some of the main existing regulations. The
flexible tube must not be reach in any point a temperatu-
re higher than 90°C, it should not be no longer than 1,5m.
It should not be subjected to any kind of traction or torsion
and it should not be allowed to be excessively bent. An
easy access should be allowed to periodically check its
condition.
Should any leaking occur, do not repair il but instead
replace it.
Service
To guarantee good working order and safety, the
regulation taps should be periodically greased. Service
can be made in the following way: Remove the knobs
and the control panel after having removed the fixing
screws. Unscrew the 2 screws placed at the sides of the
burner valve shaft. Unwind the cone and clean it with
care; then spread over the valve a thin layer of grease not
soluble by hydrocarbon. Pay attention to the fact that
too much grease can obstruct the passage of gas. To fit
again the burner valve in the normal position, you should
reverse the procedure outlined above.
22