Before requesting service, perform the following checks:
Symptom
Problem
SeePage
NORMAL
Doesn't operate
• Ifthe unit is stopped and then immediately started again, the com-
FUNCTION
immediately:
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.
-
• Whenever the Power Supply Plug is disconnected and then re­
connected to a power outlet, the protection circuit will operate for
about 3 minutes, preventing unit operation during that period.
Noise is heard:
• During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner's piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).
-
• During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.
• During Heating operation, a sizzling sound may be heard occasional.
17
This sound is produced by the Automatic Defrosting operation.
Smells:
• Some smell may be emitted from the indoor unit. This smell is
I
the result of room smells (furniture, tobacco, etc.) which have
-
been taken into the air conditioner.
Mist or steam are
• During Cooling or Dry operation, a thin mist may be seen emitted
emitted:
from the indoor unit. This results from the sudden Cooling of
-
room air by the air emitted from the air conditioner, resulting in
condensation and misting.
• During Heating operation, the outdoor unit's fan may stop, and
steam may be seen rising from the unit This is due to Automatic
17
Defrosting operation.
Airflow is weak or stops:
• When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.
• During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
I
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.
I •
During Heating operation, the unit will temporarily stop opera­
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
17
operates. During Automatic Defrosting operation, the OPERATION
i
indicator lamp will flash.
• The fan may operate at very low speed during Dry operation or
5
i
when the unit is monitoring the room's temperature.
i
• During SUPER QUIET operation, the fan will operate at very low
5
speed.
• In the monitor AUTO operation, the fan will operate at very low
5
speed.
Water is produced from
• During Heating operation, water may be produced from the out­
17
the outdoor unit:
i
door unit due to Automatic Defrosting operation.
The AIR CLEAN indicator
I.
After approximately 400 hours of Air Cleaning Mode use, the AIR
lamp (green) will begin to
i
CLEAN indicator lamp will begin to flash slowly (as shown in the
slowly flash (as shown in
figure). When this occurs, please stop the system, remove the
13 - 14
the figure):
mains socket and carry out maintenance on the dust collecting
unit's air filter.
The AIR CLEAN indicator
• After approximately 500 hours of Air Cleaning Mode use, the AIR
lamp (green) will begin to
CLEAN indicator lamp will begin to flash quickly (as shown in the
flash quickly (as shown in
figure). At this point, Air Cleaning will stop functioning. Please
13 - 14
I
the figure):
stop the system, remove the mains socket and carry out
maintenance on the dust collecting unit's air filter.
-~'"
,------­
i