Something Not Working?
If the appliance is not working correctly, please carry out the following checks before contacting your local Service
Centre.
SYMPTOM
There is no spark when lighting the gas
The gas ring burns unevenly
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.
Instructions for the Installer
Engineer technical data
Overall dimensions
Width:
580 mm
Depth:
500 mm
Height:
84 mm
Cut out dimensions
Width:
550 mm
Depth:
470 mm
Burner
Auxiliary
Semi-rapid
Triple crown
(*) 1 mbar = 10 mm. water coloumn.
Nominal Power LPG (Butane "A")
kW
kCal/h
Nozzle
0,95
814
50
1,60
1368
65
3,60
3080
98
SOLUTION
Check that the unit is plugged in and the electrical
supply is switched on.
Check the mains fuse has not blown.
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Check the main jet is not blocked and the burner
crown is clear of food particles.
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Supply Connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50 Hz supply, 3 core flexible cable with non
rewireable plug.
Appliance Gas supply: LPG 30 mbar
Appliance Class: 3
Appliance category: I 3
Diameter
Tap. By-Pass
g/h
75
28
126
35
284
56
Feeding
Pressure
mbar (*)
30
7