Electrical Connection - Zanussi ZOU 668 Instruction Booklet

Built-under ovens
Table of Contents

Advertisement

Instructions for the installer
The instructions given below are
designed specifically for a qualified
installer and should aid him or her to
perform all installation, adjustment,
and maintenance operations with
absolute precision and in compliance
with all current legislation and
regulations. We strongly recommend
that all operations for the installation
of your cooker be carryed out by
Qualified Personnel in accordance
with existing rules and regulations.

Electrical connection

Prior to making the electrical connection,
make sure that:
— the protection fuse and the domestic wiring
system are suitable to carry the total electric
load of the oven (see rating plate);
— your domestic wiring system has an efficient
earth connection in compliance with rules
and laws in force;
— the wall socket or the omnipole switch used
for the electrical connection can easily be
reached after the oven is built in.
This appliance is delivered without an
electric supply cable, therefore, you will have
to fit to it a supply cable with standard plug,
suitable for the total electric load shown on
the rating plate. The plug is to be inserted
into a suitable wall socket. If you require a
direct connection to the electric network
(mains), it will be necessary to fit between
the appliance and the mains an omnipole
switch, with a minimum gap between
contacts of 3 mm, suitable for the required
load and in compliance with rules in force.
The green & yellow ground wire must not be
interrupted by the switch, and should be 2-
3 cm longer than the phase and neutral
wires. The supply cable must in all cases
be laid out in such a way as to ensure that
it does not reach at any given point a
22
temperature 50 °C higher than the ambient
temperature.
Suitable power supply cables are the
following types, considering the respective
necessary section of cable: H07 RN-F, H05
RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F
(T90), H05 BB-F.
Connecting the terminal board
The appliance incorporates an easily
accessible 6-pole terminal board whose
jumpers (bridges) are already pre-set for
operation on 400 V tri-phase with neutral wire
(Fig. 10). In case a different mains voltage
is present, the jumpers on the terminal board
must be rearranged as shown in the diagram
(Fig.11). The ground cable must be
connected to terminal
the supply cable to the terminal board,
secure it with a junction clamp.
FO 0330
Fig. 10
230V 3~
230V 1~
400V 2N~
400V 3N~
Fig. 11
FO 0584
. After connecting
1 2 3 4 5
Querschintt
4 x 1.5 mm
L1
L2
L3 PE
1 2 3 4 5
Querschintt
3 x 2.5 mm
L1
N
PE
1 2 3 4 5
Querschnitt
4 x 2.5 mm
L1 L2
N
PE
1 2 3 4 5
Querschnitt
5 x 1.5 mm
L1 L2 L3 N
PE
(min.)
2
(min.)
2
(min.)
2
(min.)
2