Yamaha YZF-R6 99 Service Manual page 381

Motorcycle yzf-r6 99 5eb-ae1
Table of Contents

Advertisement

EB807400
5. Radiator fan motor (test 2)
S Disconnect the thermo switch coupler.
S Set the main switch to "ON".
S Connect the brown
with a jumper lead
S Does the radiator fan motor turn?
YES
6. Thermo switch
S Remove the thermo switch from the radiator.
S Connect the pocket tester (
mo switch
as shown.
1
S Immerse the thermo switch in a container
filled with coolant
2
NOTE:
Make sure that the thermo switch terminals
do not get wet.
S Place a thermometer
S Slowly heat the coolant, then let it cool to the
specified temperature as indicated in the
table.
S Check the thermo switch for continuity at the
temperatures indicated in the table.
and blue
terminals
1
2
as shown.
3
NO
The
wiring
circuit
from the main switch
to the radiator fan mo-
tor coupler is faulty
and must be repaired.
1) to the ther-
.
in the coolant.
3
COOLING SYSTEM
Coolant temperature
Test
step
Thermo switch
0 X 105
*
*
1
*
*
2
More than 105
*
*
3
105
3_C to 100
*
*
4
Less than 100
Test steps 1 & 2: Heating phase
*
Test steps 3
& 4
WARNING
S Handle the thermo switch with special
care.
S Never subject the thermo switch to
strong shocks. If the thermo switch is
dropped, replace it.
Thermo switch
28 Nm (2.8 mSkg)
Three bond sealock 10
A
The thermo switch circuit is open and the ra-
diator fan is off.
The thermo switch circuit is closed and the
B
radiator fan is on.
8-47
ELEC
Continuity
3_C
NO
3_C
YES
3_C
YES
3_C
NO
*
: Cooling phase