INSTALLER SET-UP
To enter the installer set-up mode:
a) Press the OFF button.
b) Press and hold the INFO
buttons '< >' together.
c) The unit will display the first parameter of installer
parameter group category 1 (from n.1 to n.19).
d) Press the TEMP
or
setting. The display will flash indicating that a change has
been made.
e) Press the green OK button to confirm this change and the
display will stop flashing.
f) Press the
+ button to go to the next parameter.
g) Press the program button
Installer mode (from n.1 to n.5).
h) To exit the installer mode, press the AUTO, MAN or OFF
buttons.
In Installer set-up we can:
❑ Set-up specific applications
❑ Enable special features
Specific Applications
Heating
Gas Boilers
(<30KW)
Oil Boiler
Thermal Actuator
Zone valve
Electric heating
(for applications
<5A)
i
button and the two program
buttons
to change the factory
>
to go to category 2 in the
Setting
Minimum
Cycle/
Hour
ON time
(in minutes)
6
1
3
4
12
1
6
1
12
1
Installer Set-up Number
(Press
+ or - to change)
e.g. 1 = Clock Format
What do you need to change?
Note :
a. To change Cycle/Hour, please go to parameter n. 2, category 2
in the installer set-up mode.
b. To change Minimum ON Time, please go to parameter n. 1,
category 2 in the installer set-up mode.
No action required
1. Set Minimum ON Time to 4 minutes.
2. Set Cycle/Hour to 3.
Set Cycle/Hour to 12.
No action required.
Set Cycle/Hour to 12.
3