Optional Wing Extensions
Optional wing extensions are made for fireplace open-
ings which are larger than the cast wing. The 3 piece
wing extension is 48" wide by 34"high.
Custom oversized wing extensions can be purchased
from Harman for any fireplace openings larger than the
standard wing extension area.
These optional wing extensions will have a 1/2 inch re-
turn bend as shown in fig. 20. Custom oversized wing
extensions with a radius top can be ordered with a ra-
dius of your choosing. These radius top wings WILL
NOT have a return bend, although they will be made of
thicker metal to reduce warpage.
Fig. 20
5. The power cord can be installed exiting the left
(standard) or right side of the surround. If a right side
cord is desired, follow the instructions below.
Changing the cord exit location from the left side
to the right side:
The cord is located on the left side, standard from
Harman. (See fig 21.)
To route the cord to the right side:
• Cut the tyraps looping the cord to the left
• Reroute the cord along the top of the steel angle and
down the right side.
• Re-tyrap (not supplied by Harman) the wire through
the notches provided in the mounting frame. Then down
the right side rail.
• Do not remove or move the cord retainer, it is made
to reach both the right and left sides.
No th in g ca n ex -
tend beyond this
face to the back
side.
Fig. 21
Installation
1/4-20 x 3/8
bottom head bolts
(5/32" allen wrench)
DO
NOT
CUT.
Connecting the cord retainer to the wing
With the three wing pieces completed, the cord re-
tainer must be bolted to the bottom rear of the wing.
Either left exit (shown in fig. 22) or right exit.
At the bottom rear edge of the right and left wing there
is a small radius indent for the cord to exit between
the wing and the fireplace face.
Fig. 22
Fig. 23
6. You must now decide whether to install the room
sensor as a wall sensor or as a return air sensor.
Harman highly recommends that the room sensor be
installed. If you are installing the room sensor as a wall
sensor, the long black 2 wire cable must be Ty-rapped
to the powercord. This wire is long enough to reach the
end of the power cord so the installer can reach past
the hearth to the location where the extension wire (18/
2 thermostat wire, not supplied by Harman) can be
spliced to go to the wall location chosen for the room
sensor.
(5/32" allen wrench)
Ground
Ty-raps
12