Remove terminal block access cover from range back. (See
figure 9).
For service cord (pigtail) use, remove knockout ring from
conduit plate. (See figures 10A and 10C).
I
!
3-WIRE
SERVICE
CORD INSTALLATION
FIGURE
IOA
1. Insure that the copper ground strap IS CONNECTED
between the middle post of the main terminal connection
block and the range chassis.
.
The middle wire of the service cord MUST connect to the
neutral (middle) post of the main terminal connection
block. The other two wires of the service cord connect to
the outside posts of the main terminal connection block.
Polarity is unimportant.
3. Position strain relief with flanges on top of conduit plate
as shown and secure to service cord.
3--WIRE CONDUIT
INSTALLATION
FIGURE
lOB
1. The
range
conduit
must be routed and properly
connected to an approved electrical junction box behind
the range.
2. The red and black wires from the range conduit must
respectively connect to the red and black service wires.
An approved wire connector must be used.
3. Both the white wire and the uninsulated (bare) wire from
the conduit should connect to the white service wire as
shown. The bare wire is the range chassis ground.
4-WIRE
SERVICE
CORD INSTALLATION
(MOBILE HOMES)
FIGURE
10C
.
The copper ground strap connected between the neutral
(middle) post of the main terminal block and the chassis
MUST be removed and discarded.
Keep the green
ground screw. Only a 4 conductor cord should be used.
2. The green wire from the service cord must connect to the
range chassis using the green ground screw.
.
The white wire of the service cord must connect to the
neutral (middle) post of the main terminal block. The
other two wires of the service cord connect to the red and
black posts of the main terminal block, respectively.
4. Position the strain relief with flanges on top of conduit
plate as shown and secure to service cord.
4-WIRE
CONDUIT
INSTALLATION
(MOBILE HOMES)
FIGURE
I OD
1. The
range conduit must
be routed and properly
connected to an approved electrical junction box behind
the range.
2. The red and black wires from the range conduit must
respectively connect to the red and black service wires.
An approved wire connector must be used.
3. The white wire from the conduit must be connected to the
white service wire.
4. The uninsulated (bare) wire from the conduit must be
connected either to a green or bare service wire.
CONVERSION
FROM
3-WIRE
TO 4-WIRE
SERVICE
(Free-Standing
Models Only With 3-Wire Service Cord
Attached).
Disconnect range from power. Remove the access cover on
back of range and remove the 3-wire service cord from the
main terminal block. Follow instructionsas outlined in figure
10C to connect the 4-wire service cord.
NOTE: Cord replacement - ONLY a power supply cord
rated at 240 volts minimum, 40 amperes or 50 amperes
power supply cord that is marked for use with nominal I 3/8"
(34.93 mm) diameter connection opening, with closed loop
terminals and marked for use with ranges shall be used.
_'7_