INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed:
[] 200 mm (8") or 250 mm
[]
8 mm (5_6")socket wrench
(10") Pipe wrench
[]
Utility knife
[] 200 mm (8") or 250 mm
[] Vent clamps
(10") Adjustable wrench
[]
Caulk gun and caulk
[]
Flat-blade screwdriver
(for installing new
[]
Phillips screwdriver
exhaust vent)
[] Adjustable
wrench that
[]
Pliers
opens to 25 mm (1 ") or
[]
Stiff-bladed putty knife
hex-head socket wrench
[]
Level
Parts supplied:
Remove parts bag from dryer drum. Check that all parts were
included.
[]
Foot boot (4)
[]
Dryer foot (4)
NOTE: The circuit diagram for this dryer is located inside the
lower front panel.
Technical
Specifications:
220 - 240 V, 50 Hz. AC
Clothes Capacity:
9 Kg Max.
Explosion
Hazard
Keep flammable
materials
and vapors, such as petrol,
away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion,
or fire,
IMPORTANT: Observe all governing codes and ordinances.
[]
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
NOTE: The dryer must not be installed in an area where it will be
exposed to water and/or weather.
Recessed
Area and Closet
Installation
instructions
This dryer may be installed in a recessed area or closet. This
dryer must not be installed behind a Iockable door, a sliding door,
or a door with a hinge on the opposite side to that on the dryer.
The installation spacing is in mm and is the minimum allowable.
Additional spacing should be considered for ease of installation,
servicing, and compliance with local codes and ordinances.
If installed in a closet with a door, the minimum unobstructed
air
opening in the top and bottom is required. Louvered doors
with equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Minimum Installation
Clearances
o{o
381 mm
(15")*
f
Inl
I
o mm(o")
Recessed front
0 mm(0")
view
356 mm
--
(14") max.
Closet
door
r--
0 m_
(0")
{_r----25 mm(1")
Closet side view
* Additional
clearances for wall, door, and floor moldings may be required
or if external exhaust elbow is used.
310 cm 2
(48 in_.)*
Front
View
O
closet
door
L
76 mm (3")
* Opening is the minimum for
a closet door. Louvered doors
with equivalent air openings
are acceptable.
76 mm (3")
+