30
HP ProLiant DL380 Generation 3 Server User Guide
PCI Hot Plug LED Status Combinations
Power LED
Fault LED
(Green)
(Amber)
On
Off
On
On
Flashing
On or off
Off
On
Off
Off
OK to
Slot Status
open?
No
The power to the slot is on and the slot is functioning
normally. Do NOT open the slot release lever.
No
The power to the slot is on, but the slot needs attention for a
possible problem with the slot, board, or driver. DO NOT
open the slot release lever.
Examine the logs and Insight Manager 7. If the expansion
board is faulty, remove or replace the board.
No
The power to the slot is being turned off or on, which may
take several seconds. DO NOT open the slot release lever.
To cancel the operation, press the PCI Hot Plug button.
Yes
The power to the slot is off, but the slot needs attention for a
possible problem with the slot, board, or driver.
Yes
The power to the slot is off.