Worcester PRIMARY WATER STORAGE 120 LITRES Installation And Servicing Instructions
Worcester PRIMARY WATER STORAGE 120 LITRES Installation And Servicing Instructions

Worcester PRIMARY WATER STORAGE 120 LITRES Installation And Servicing Instructions

Primary water storage 120 litres

Advertisement

Quick Links

Installation and Servicing Instructions
PRIMARY WATER STORAGE 120 LITRES
UK/IE

Advertisement

Table of Contents
loading

Summary of Contents for Worcester PRIMARY WATER STORAGE 120 LITRES

  • Page 1 Installation and Servicing Instructions PRIMARY WATER STORAGE 120 LITRES UK/IE...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Safety precautions & explanation of symbols 3 Safety precautions Explanation of symbols Product information Intended use Scope of delivery Dimensions and connections Technical data Installation Regulations Disposal Transport Means of transport Installation location Fitting Fitting the bolts Fitting the temperature sensor Connection of the storage tank to the heat pump...
  • Page 3: Safety Precautions & Explanation Of Symbols

    Safety precautions and explanation of symbols Safety precautions and explanation of symbols Safety precautions Additional symbols Symbol Meaning Fitting & Retrofitting V Risk of fire! a step in an action sequence Exercise due care when soldering and welding as this a reference to a related part in the docu- can lead to fire.
  • Page 4: Product Information

    Product information Product information The storage tank is designed to act as a buffer for the heating system and is ideally suited to heat pump applications. Warning: V Do not use the storage tank in conjunction with permeable pipework. Intended use The storage tank must only be filled with heating water and must only be used in sealed heating systems which are designed for use with heat pumps.
  • Page 5: Dimensions And Connections

    Product information Dimensions and connections Fig. 2 Dimensions and connections (dimensions in mm) flow (heat pump) flow (heating) return (heat pump) return (heating) measuring point for flow temperature sensor measuring point for return temperature sensor (GT1) - from heat pump drain valve air vent Technical data...
  • Page 6: Installation

    Installation Installation Regulations This appliance must be installed and serviced only by a competent person in accordance with the current: IEE Regulations, Building Regulations, Building Standards (Scotland) (Consolidation), Building Regulations (Northern Ireland), local water by-laws, Health and Safety Document 63S (the Electricity at Work Regulations 1989, IS813 (Eire) and other local requirements...
  • Page 7: Transport

    Transport Transport Means of transport Danger: Risk of injury from carrying heavy weights! V Do not try to lift or carry the storage tank alone. Caution: Damage from inappropriate pro- tection during transport! V For transport, use appropriate means, e. g. a sack truck or pump truck with a tension belt.
  • Page 8: Fitting

    Fitting Fitting Fitting the bolts V Place the polystyrene packaging[1] on the floor. V Lay the storage tank [2] on the polystyrene with care. V Fit the M10 x 30mm bolts [3] accordingly into the bottom of the storage tank. V Adjust the bolts to level the tank.
  • Page 9: Connection Of The Storage Tank To The Heat Pump And Heating System

    Fitting Connection of the storage tank to the heat pump and heating system Danger: Risk of fire from soldering and welding! V Take suitable safety measures when soldering and welding. V When sizing the heating system expansion vessel, take the storage tank volume into consideration. Caution: Risk of damage to non heat-resist- ant installation materials (e.
  • Page 10: Initial Operation

    Initial operation Initial operation Customer handover The installer explains to the customer (user) the mode of operation and the handling of the heating appliance and the storage tank. V Make the user aware of the mode of operation. V Hand all enclosed documents over to the user. Start of operation Start of operation has to be done by the installer of the heating system or by a technical expert.
  • Page 11: Decommissioning The System

    (or other accessories) instruction manual. Environmental protection Environmental protection is a key company commiment fo the Bosch Group. Quality of performance, efficiency and environmental pro- tection are our long term objectives. Legal and corporate guidelines are strictly adhered to.
  • Page 12: Servicing

    Servicing Servicing Service and commissioning Apart from occasional visual inspection, storage tanks do not require any particular servicing or cleaning. V Use original spare parts only! Emptying Warning: Risk of scalding! Hot water can lead to major scalding V Allow the storage tank time to cool down after decommissioning.
  • Page 13 Notes 8 716 115 670 (02/2009)
  • Page 14 Notes 8 716 115 670 (02/2009)
  • Page 15 8 716 115 670 (02/2009)
  • Page 16 SALES: 01905 752640 WEBSITE: www.worcester-bosch.co.uk Dedicated to heating comfort Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW Tel. 01905 754624 Fax. 01905 754619 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. www.worcester-bosch.co.uk 8 716 115 670a...