Installation Instructions; Install Anti-Tip Bracket - KitchenAid KGRS505XWH04 Installation Instructions Manual

30" (76.2 cm) double oven gas ranges
Table of Contents

Advertisement

Available languages

Available languages

GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
Explosion Hazard
Use a new CSA International
approved
gas supply line.
Install a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
t!..l ;;_
S _:.,_,,,0
_.?'÷ _'S!O_S
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shutoff valve to the closed position.
.......................................................................
B
A_
...................................
C
A. Torange
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug range or disconnect
power.
To Convert Gas Pressure Regulator
1. Locate gas )ressure regulator at the rear of the range.
_
_
o
A. Gas pressure regulator
IMPORTANT:
Do not remove the gas pressure regulator.
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents