Power S upply Cord
Direct W ire
Electrical
Shock Hazard
Disconnect
power before servicing.
Use a new 40 amp power supply
cord.
Plug into a grounded
outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge alurninum
wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1=
2.
3=
Disconnect
power.
Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover.
"__
,////
A. Hold-down
screws
B. Terminal block cover
Add strain relief,
Style 1: Power supply cord strain relief
Remove the knockout for the 40-amp supply cord.
Assemble a UL listed strain relief in the opening,
Feed the power supply cord behind the black horizontal
cross brace and through the strain relief, allowing enough
slack to easily attach the wiring to the terminal block.
A. Black horizontal cross brace
B. Power supply cord
Tighten strain relief screw against the power supply cord,
A. UL listed strain relief