KitchenAid KDRS505XSS00 Installation Instructions Manual page 15

30" (76.2 cm) double oven dual fuel ranges
Hide thumbs Also See for KDRS505XSS00:
Table of Contents

Advertisement

Available languages

Available languages

3=
Pull the conduit through the strain relief on cord/conduit
plate
on bottom of range. Allow enough slack to easily attach wiring
to the terminal block.
!,?! ........... ,
L
.......
I
®.......... , .......
,
i _ '
i
'_,
il
i
.....
g
;w
I
i
i
/
C
4,
G
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Line 2 (red) wire
E. Neutral
(white)
wire
F. Line
1 (black)
wire
G. Bare
(green)
ground
wire
Attach terminal lugs (located in the package containing
literature) to line 1 (black), neutral (white), and line 2 (red) wires.
Loosen (do not remove) the setscrew on the front of the
terminal lug and insert exposed wire end through bottom of
terminal lugs. Securely tighten setscrew to
XX Ibs-in. torque. See Bare Wire Torque Specifications
chart.
!
!
!
!
C
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
D. Neutral (white) wire
E. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 Ibs-in. (2.8 N-m)
6 gauge aluminum
35 Ibs-in. (4.0 N-m)
5,
6=
Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link screw. The ground wire
must be attached first and must not contact any other
terminal.
Use 3/8"nut driver to connect the neutral (white) lug to the
center terminal block post with one of the 10-32 hex nuts.
B
F
D
/
E
C
A. 10-32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-link
screw
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
7. Connect line 1 (black) and line 2 (red) terminal lugs to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
3-wire connection:
Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Pull the conduit through the hole and conduit plate on bottom
of range. Allow enough slack to easily attach the wiring to the
terminal block.
LJ
I
::::::: ............
B
i
C
F
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
15