FURNACE OVERHEAT HAZARD
Failure
to follow
this
caution
may
result
in unit
component
damage.
Connect
gas pipe to gas valve
using a backup
wrench to avoid damaging gas controls and burner
misatiqnment.
An accessible
manual equipment
shutoff valve MUST be
installed external to furnace casing and within 6 ft. (1.8 M) of
furnace. A 1/8-in.
(3 mm) NPT plugged tapping, accessible
for test gauge connection,
MUST be installed
immediately
upstream
of
gas
supply
connection
to
furnace
and
downstream
of manual equipment shutoff valve.
NOTE:
The furnace gas valve inlet pressure tap connection
is suitable to use as test gauge connection
providing
test
pressure DOES NOT exceed maximum 0.5 psig (14-in. w.c.)
stated on gas control valve. (See Figure 41)
Figure 21 - Burner and Manifold
TOP VIEW OF BURNER
AND
MANIFOLD
ASSEMBLY
2" (51 ram)Nipple
Street
Supply
t-Gas
Valve
A08551
Figure 22 - Typical Gas Pipe Arrangement
GAS--
SUPPLY
j'"_
MANUAL J
II
SHUTOFF
_
_
VALVE
(REQUIRED)_ "1_
}_
SEDIMENT--
/
TRAP
/
UNION.-.J
A02035
Some installations
require gas entry on right side of furnace
(as viewed in upflow.) (See Figure 21)
Install a sediment trap in riser leading to furnace as shown in
Figure 22. Connect a capped nipple into lower end of tee.
Capped
nipple should
extend below level of furnace gas
controls.
Place a ground joint union between furnace gas
control valve and exterior manual
equipment
gas shutoff
valve. A 1/8-in. (3 mm) NPT plugged tapping, accessible for
test
gauge
connection,
MUST
be installed
immediately
upstream
of
gas
supply
connection
to
furnace
and
downstream
of manual equipment shutoff valve.
Piping should be pressure and leak tested in accordance with
NFGC, local, and national plumbing
and gas codes before
the furnace has been connected. After all connections have
been made, purge lines and check for leakage at furnace
prior to operating furnace.
If pressure exceeds 0.5 psig (14-in. w.c.), gas supply pipe
must be disconnected
from furnace and capped before and
during supply pipe pressure test. If test pressure is equal to or
less than 0.5 psig (14-in. w.c.), turn off electric shutoff switch
located on furnace gas control valve and accessible
manual
equipment
shutoff
valve
before and
during
supply
pipe
pressure test. After all connections
have been made, purge
lines and check for leakage at furnace prior to operating
furnace.
Figure 23 - Relocating
J-Box
FACTORY
INSTALLED
LOCATION
ALTERNATE
FIELD
LOCATION
Figure 24 - Field-Supplied
Electrical Box on Furnace
Casing
O
The gas supply pressure shall be within the maximum and
minimum
inlet supply pressures marked on the rating plate
with the furnace burners ON and OFF.
441 01 1402 02