Technical Specifications - HP ProLiant DL585 Quickspecs

Hp proliant generation 2(g2)
Hide thumbs Also See for ProLiant DL585:

Advertisement

QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions (H x W x D)
Dimensions
Dimensions
(with bezel)
Weight
Weight
Weight
Weight
(approximate)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Power Specifications
Power Specifications
Power Specifications
Power Specifications
Power Supply Output (per
Power Supply Output
Power Supply Output
Power Supply Output
power supply)
System Inlet Temperature Operating
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
DA - 12575
North America — Version 39 — July 16, 2008
6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/powercalcs.asp
Click on the system of interest. Example: DL585 G2
Follow the instructions of the next screens
Rated Steady-State Power
Maximum Peak Power
Non-operating
Operating
Non-operating
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
95 lb (43 kg)
79 lb (36 kg)
90 - 132 VAC,
180 - 264 VAC
12 A (at 100 VAC),
8 A (at 200 VAC)
47 to 63 Hz
1161 W (at 100 VAC),
1598 W (at 200 VAC)
3985 BTU/hr (at 100 VAC),
5457 BTU/hr (at 200 VAC)
910 W (at 100 VAC),
1300 W (at 200 VAC)
960 W (at 100 VAC),
1420 W (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Page 42