5. Adjust the "LOW"Settingof the DualBurner
(seeFigure8) on the SurfaceBurnerValve(Figure
10):
Note:Onthedualvalve thelowsettingof each portion
(rearportionof bridgeburner andthe centerportion of
bridgeburner) s houldbeadjusted individually.
a. Push in andturn control t o LITE untilthe rearportion
of the bridgeburner ignites only.
b. Quicklyturn knobto LOWEST POSITION.
c. If burner g oesout,reset c ontrol t o OFF.
d. Remove t hesurface burner control k nob.
e. Theinnerportionof thedualburner flamesize canbe
increased or decreased byturningscrew A (see Figure
19).Usescrew Bto adjust t heflamesizeofthe outer
portion of the dualburner. T urn counterclockwise
the screw to increase f lamesize. T urn clockwise t he
screw to decrease flamesize. A djust f lameuntilyou
canquickly turn knobfromLITE to LOWEST POSITION
withoutextinguishing theflame.Flame shouldbeas
small a spossible w ithoutgoingout.
Note:Air mixture adjustment isnot required onsurface
burners.
When All Hookups
are Complete
Make sure all controls are left in the OFF position.
Before You Call for Service
Read the Before You Call for Service Checklist and
operating instructions in your Use and Care Guide.
It may save you time and expense. The list includes
common occurrences that are not the result of defective
workmanship or materials in this appliance.
Refer to your Use and Care Guide for Electrolux Service
phone numbers, or call 1-877-4ELECTROLUX (1-877-
435-3287).
Figure 10