Electrolux EI30SM55JWA Installation Instructions Manual

Over the range microwave oven
Hide thumbs Also See for EI30SM55JWA:

Advertisement

Available languages

Available languages

|NSTALLA'rioN
INsrRucrIoNS
BEFORE
YOU
BEGIN
Readthese instructionscompletely andcarefully.
• _
Save these instructions for local
inspector's use.
• _
Observe all governing codes and
coordinates.
• NOTI;'
TO
iNSTALLER
- Be sure to leave these
instructions with the Consumer.
• NOTE
TO CONSUMER
- Keep these instructions for
future reference.
• SKILL
LEVEL-
Installation of this appliance requires
basic mechanical
and electrical skills.
Proper installation is the responsibility
of the installer.
Product failure due to improper
installation is not covered
under the Warranty.
Please
read all instructions
thoroughly
before installing
the Over the Range
Microwave
Oven. Two people
are
recommended
to install this product.
If a new electrical
outlet is required, its installation should
be completed by a qualified electrician before the Over the
Range Microwave Oven is installed. See 3 ELECTRICAL
GROUNDING
INSTRUCTIONS
on page 2.
1 MOUNTING SPACE
This Over the Range Microwave Oven requires a mounting
space on a wall as shown in Figure 1. It is designed to be
used with standard 12" wall cabinets.
Backsplash
Atleast2"
30"or more
from cooking
surface
i
FiguPe 1
66" or more
from floor
2 WALL CONSTRUCTION
This Over the Range Microwave Oven should be mounted
against and supported
by a flat vertical wall. The wall must
be flat for proper installation. If the wall is not flat, use spacers
to fill in the gaps. Wall construction
should be a minimum of
2"x 4" wood studding and 3/8"or more thick dry wall or plaster/lath.
The mounting surfaces must be capable of supporting weight
of 110 pounds--the
oven and contents--AND
the weight of
all items which would normally be stored in the top cabinet
above the unit.
The unit should be attached to a minimum
of one 2" x 4"
wall stud.
To find the location of the studs, one of the following methods
may be used:
A. Use a stud finder, a magnetic device which locates the
nails in the stud.
B. Use a hammer to tap lightly across the mounting surface
to find a solid sound. This will indicate stud location.
The center of the stud can be located by probing the wall with
a small nail to find the edges of the stud and then placing a
mark halfway between the edges. The center of any adjacent
studs will normally be 16" or 24" to either side of this mark.
NEED HELP?
For customers
in the United States and Canada
United States: 1-800-944-9044
Canada: 1-800-265-8352
READ CAREFULLY.
KEEP THESE INSTRUCTIONS.
316495060
TINSEB196WBRZ-EL82
Printedin Thailand

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux EI30SM55JWA

  • Page 1 INsrRucrIoNS |NSTALLA'rioN BEFORE BEGIN Readthese instructionscompletely andcarefully. • _ Save these instructions for local • Proper installation is the responsibility of the installer. inspector's use. • Product failure due to improper installation is not covered under the Warranty. • _ Observe all governing codes and coordinates.
  • Page 2: Electrical Grounding Instructions

    140 feet. electrical instructions, consult a qualified electrician serviceperson. 2. Neither Electrolux nor the dealer can accept any liability for damage to the oven or personal injury resulting from failure to observe the correct electrical connection procedures. 90° Elbow (10ft.) 45°...
  • Page 3: Tools Recommended For Installation

    Scissors broken or loose door hinges and latches and dents inside the cavity or on the door. If there is any damage, do not Pencil operate the oven and contact your dealer or Electrolux Measure AUTHORIZED SERVICER. Tape...
  • Page 4: Ventilation System

    8 VENTiLATiON SYSTEM HORIZONTAL EXHAUST: OUTSIDE VENTILATION (PREPARINGOVENFOB iNSTALLATiON) Remove 3 screws from back edge and 5 screws from the top of Fan Cover Bracket. Save 3 screws to use them to This Over the Range Microwave Oven is designed attach Exhaust Damper Assembly to the wall later and adaptation to three types of hood ventilation systems.
  • Page 5 VERTICAL EXHAUST: O UTSIDE VENTiLATiON Rotate 180 ° FanBlade Openings Remove and save 3 screws from back edge and 5 screws from the top of the Fan Cover Bracket to use at Step 5. Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket as shown in Figure 11.
  • Page 6 Position Mounting Plate with the Toggle Bolts attached at the wall location and insert Toggle Nuts and Bolts through the holes in the wall with the Toggle Nuts closed. See Figure 16. Use Wood Screws to attach the Mounting Plate to studs. NOTE:Before insertion, be sure you leave a space more than the thickness of the walt between the Mounting Plate and the end of each of the Toggle Nuts (in the closed...
  • Page 7: Checklist Forinstallation

    CHECKLIST FORiNSTALLATiON 1. Make sure the unit has been installed according to all of the Installation Instructions and the Wall and Top Cabinet Templates. 2. Plug in the power cord. 3. Keep these Installation Instructions. NOTE: Make sure to remove the tape at the turntable support before operation.
  • Page 9 |HSrRU NES DE INSTALAC|ON ANTES DiE COMENZAR Lea estasinstrucciones comp/eta y detal/adamente. Guarde estas instrucciones para uso del • La correcta instalaci6n es responsabilidad del instalador inspector local. • La garantia no cubre la falta del producto por instataci6n inapropiada. Cumpla con los c6digos y normas vigentes.
  • Page 10 INSTBUCCIONES D ECONEXI6N A TiEBBA DUCTODEESCAPE DECAIVlPANA ELECTRiCA EXTBACTOBA Este aparato debe conectarse a tierra. Este homo esta Cuando la campana extractora tiene escape hacia el equipado con un cable que tiene un alambre de tierra y exterior, se requiere un ducto de escape de campana. Todo enchufe con pata de tierra.
  • Page 11 L&piz con el PROVEEDOR DE SERVlClOAUTORIZADO Cinta para medir ELECTROLUX. 6 HERRAJES DEINSTALACION Los elementos de la tornilleria de instalaci6n del d) - <6) e sta.n en una botsa pequeSa. Todos los elementos se encuentran en una caja de cartdn debajo del homo.
  • Page 12 8 SISTEIVlA DEVENTILACION ESCAPE HORIZONTAL: EXTRACCION HACIAELEXTERIOR (PREPARACIONDEL HOBNOPABASU INSTALACI(]N) Retire 3 tornillos del borde posterior y 5 tornillos de la parte superior del soporte de la cubierta det ventilador. Este Horno microondas sobre la estufa esta. dise_ado Guarde los 3 torniltos para utitizarlos ma.s tarde para fijar el conjunto del amortiguador de escape a la pared para adaptarse...
  • Page 13 ESCAPE VERTICAL: EXTRACCl0N HAClA E LEXTERIOR Gire 180 ° Orificiosde las Paletas del Ventilador Retire y guarde 3 tomillos del borde posterior tomiltos de la parte superior del soporte de la cubierta del ventitador para utitizarlos en el Paso 5. Retire el soporte de la cubierta del ventilador destiz_.ndolo en la direcci6n opuesta a la flecha en el soporte de la cubierta del ventilador, segQn se muestra en la Figura 11.
  • Page 14 (B) 0rifici0sdelasPaletas Coloque la Placa de Montaje con los Pemos de Anclaje del V entilad0r sujetados, en el sitio de pared e inserte los Pemos y Tuercas de Anctaje a traves de los orificios en la pared (A)Gire 90° con las Tuercas de Anclaje cerradas. Vea la Figura 16. Utilice Tornitlos para Madera.
  • Page 15 LISTADEVERIFICACION PARAINSTALACION 1. AsegOrese que la unidad ha sido instalada de acuerdo con todas las Instrucciones de Instalaci6n y las Plantillas de Pared y las Plantillas del Gabinete Superior. 2. Enchufe el cable de energia. 3. Conserve estas Instrucciones de instalaci6n. NOTA: LengSetas Aseg_rese de retirar la cinta del soporte del plato giratorio antes...
  • Page 17: Espace Demontage

    iiNSTALLAr|Oll D'INS rRUCTIION AVANT DE COMMENCER Life attentivement l a totalit_de cesinstructions. Conserver ces instructions pour I'inspecteur L'installateur est responsable de sa bonne installation. local. Une panne du produit due a une mauvaise installation n'est Observer tousles reglements et les pas couverte par la garantie.
  • Page 18 & la terre, consultez un electricien de moins de 140 pi. (42,7 m). de metier ou un reparateur qualifie. 2. Ni Electrolux nile revendeur ne peuvent accepter aucune responsabilite des deg&ts au four, ou des blessures...
  • Page 19 Si vous trouvez un quelconque dommage, ne faites Bande autocollante pas fonctionner le four et contactez votre revendeur ou UN SERVICE AGRE_E_ D E DEPANNAGE ELECTROLUX. 0 iVIATI RIEL D'INSTALLATION Les articles de quincaillerie du materiel d'installation (_ & @ sont emballes dans un petit sac.
  • Page 20 8 SYSTEME DEVENTILATION F':CHAPPEIVIENT HORIZONTAL: VENTiLATiON EXTERIEURE (PRI':'PARATION DU FOURPOUR L'INSTALLATION) Enlevez les 3 vis du bord arriere et les 5 vis au-dessus de la fixation du couvercle de ventilateur. Mettez de cete les 3 vis qui seront reutilisees pour fixer I'ensemble registre Le four &...
  • Page 21 (C) [:CHAPPEIViENT VERTICAL: VENTiLATiON EXTERIEORE 1. Enievez les 3 vis du bord arriere et les 5 vis au-dessus de ia fixation du couvercle de ventilateur pour les utiliser & I'etape 5. Enievez la fixation du couvercie de ventilateur en la faisant glisser dans le sens oppose & la fleche sur ia fixation du couvercie de ventilateur, comme illustre sur ie Schema 11.
  • Page 22 Placez la plaque de fixation avec les boulons & ailettes sur lemur et inserez les boulons a ailettes avec leurs ecrous Ouvertures pour Pales duVentilateur dans les trous dans le mur, les ailettes refermees. Voir le schema 16. Employez les visa bois pour fixer la plaque de (A)Toumez90 °...
  • Page 23 PENSE-BETE P OURL'INSTALLATION 1. Assurez-vous que I'appareil a 6t6 install6 en suivant toutes instructions et en utilisant le gabarit mural et de plafond. 2. Branchez le cordon d'alimentation secteur. 3. Conservez ces Instructions d'installation. REMAROUE: Languettesde Fixation Assurez-vous de retirer I'adh6sif sur le support de plateau tournant avant mise en fonctionnement.