If oven is used in a new branch circuit
installation
(1996 NEC), mobile
home, recreational
vehicle,
or where
local codes DO NOT permit
grounding
through
the neutral
(white)
wire, the appliance
frame MUST NOT be connected
to the neutral
wire
of the 4-wire
electrical
system. (see figure
4):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the junction box:
connect appliance and power supply cable wires as
shown in Figure 4.
Cable from Power Supply
Ground Wire i
_--_
Ground Wire __)
!
(Bare or Green
___
Wire)
/
----t
Junction Box
........
hite Wire
_,,__
Black
Wiris
White Wire
......... U.L.-Listed Conduit
Connector (or CSA
Cable from appliance
listed)
Figure 4
4-WIRE GROUNDED JUNCTION BOX
Model
and
Serial
Number
Location
The serial plate is located along the interior side trim of
the oven and visible when the door is opened.
When ordering parts for or making inquires about your
oven, always be sure to include the model and serial
numbers and a lot number or letter from the serial plate
on your oven.
Serial Plate
Location
4. Cabinet
Installation
Do not lift the oven by the door handle.
Heavy Weight
Hazard
• Use 2 or more people to move and install
wall
oven,
• Failure
to follow
this instruction
can result
in
injury or damage to the unit.
O
Unpack the wall oven. Remove the bottom trim
taped on the oven side panel.
_t
Find the 2 anti-tip mounting screws included in the
literature package.
_I
Insert the oven into the cabinet opening. Slide oven
inward leaving 11/2 '` (3.8 cm) clearance between the
oven and front of cabinet (see Figure 5).
Pull the armored cable through the hole for it in the
cabinet and toward the junction box while moving the
appliance inward.
_I
Push the oven in and against the cabinet.
...... lY2" (3.8 cm)
clearance
between
unit
Figure 5