Gas Supply Requirements - Frigidaire GLER341CC0 Installation Instructions Manual

Gas & electric dryer
Hide thumbs Also See for GLER341CC0:
Table of Contents

Advertisement

Number
of
90°
Turns
0
1
2
3
4
MAXIMUM
LENGTH
of 4" (10.2 cm) Dia. Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
Louvered
(10.2 cm)
60 R.
(18.28 m)
52It,
(15.84 m)
44ft,
(13.41 m)
32 ft.
(9,75 m)
28 ft.
(8.53 m)
(6.35cm)
48 ft,(14.63 m)
40 ft.(12.19 m)
32 ft. (9.75 m)
24 ft. (7.31 m)
16ft,
(437 m)
Number
of
90 °
Turns
0
1
2
3
MAXIMUM
LENGTH
of 4" (10.2 cm) Dia. Flexible Metal Duct
VENT HOOD TYPE
(Preferred)
Louvered
_/z"_'_'-
€10.2 cm'J
(6.35 cm)
30ft,
(9,t4m)
18ft (5.49m)
22ft,
(6,71 m)
14 ft. (4.27 m)
14ft.
(4.27 m)
10 ft. (3.05 m)
NOT RECOMMENDED
INSTALL MALE FITTINGS IN CORRECT DIRECTION
In installations where the exhaust system is not described in the
charts, the following method must be used to determine if the
exhaust system isacceptable:
1.
Connect an inclined or digital manometer between the
dryer and the point the exhaust connects to the dryer.
2.
Set the dryer timer and temperature
to air fluff (cool
down) and start the dryer.
3.
Read the measurement on the manometer.
4,
The system back pressure MUST NOT be higher than
0,75
inches of water column.
If the system back
pressure is less than 0.75 inches of water column, the
system is acceptable.
If the manometer
reading
is
higher than 0.75 inches of water column, the system is
too restrictive
and the installation
is unacceptable.
Although
vertical
orientation
of the exhaust
system is
acceptable, certain extenuating circumstances could affect the
performance of the dryer:
Only the
rigid
metal
duct work
should
be used.
Venting vertical through a roof may expose the exhaust
system to down
drafts causing an increase in vent
restriction.
Running the exhaust system through an uninsulated area
may cause condensation and faster accumulation of lint.
Compression or crimping of the exhaust system will cause
an increase in vent restriction.
The exhaust system should be inspected and cleaned a
minimum of every 18 months with normal usage. The more
the dryer is used, the more often you should check the
exhaust system and vent hood for proper operation.
EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear exhausting.
However, on electric dryers, exhausting can be to the right or
left side of the cabinet or the bottom of the dryer. On gas dryers,
exhausting can be to the right side of the cabinet or the bottom
of the dryer. Directional exhausting can be accomplished by
installing Exhaust Kit, P/N 131456800, available through your
parts distributor. Follow the instructions supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
SAME AS OTHER SIDE
I
/"
43 -I
131/2
11 cm
(93
cm)
_
"_Y/_
331,"
"-.
/
_9_ cm)
GAS SUPPLY REQUIREMENTS
Replace copper connecting
pipe that is not
plastic-coated.
Stainless steel or plastic-coated
brass MUST
be used.
1. Installation MUST conform with local codes,or in the absence
of local codes, with the National FuelGas Code, ANS! Z223.1
(latest edition) or in Canada, the current CANiCGA B149.
2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect
your dryer to the gas supply line. The tubing MUST be
constructed of stainless steel or plastic-coated brass.
4. The gas supply line MUST have an individual shutoff valve.
5. A 1/8 inch (0.32 cm) N.RT. plugged tapping, accessible for
test gauge connection,
MUST be installed immediately
upstream of the gas supply connection to the dryer
6. The dryer MUST be disconnected from the gas supply piping
system during any pressure testing of the gas supply piping
system at test pressures in excess of 1/2 psig (3.45 kPa).
7. The dryer MUST be isolated from the gas supply piping
system during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.45
kPa).