GAS FLOW
Pressure
Shutoff
Hare
_
Hare
ReguHator
VaHve
Union
Union
On, _J
t
t
t
k,_
NippHe
FHexibHe
NippHe .........................
Access
Off
Connector
Cap
All connections must be wrench4ightened
Figure 11
Assemble the flexible connecter from the gas supply pipe
to the pressure regulator in the following order:
1. manual shutoff valve (not supplied)
2. 1/2" nipple (not supplied)
3. 1/2" flare union adapter (not supplied)
4. flexible connector (not supplied)
5. 1/2" flare union adapter (not supplied)
6. 1/2" nipple (not supplied)
7. pressure regulator (supplied)
The gas supply line to the shutoff valve should be
1/2"(1,27 cm) or 3/4"(1.9
cm) solid pipe.
The user must know the location of the main shutoff
valve and have easy access to it.
When using flexible gas conduit on the range, allow
suffi(ient slack to pull the range outside the cutout for
cleaning or servicing.
NOTE: Do not allow the flexible conduit to get pinched
between the wall and the range. To visually check,
remove tile range drawer.
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors are used, be certain connectors are not kinked.
Open
position
Figure 12
Tile supply line must be equipped with an approved
manual shutoff valve. This valve should be located in the
same room as the range and should be in a location that
allows ease of opening and closing. Do not block access
to the shutoff valve. The valve is for turning on or
shutting off gas to the appliance.
Once regulator is in place, open the shutoff valve in the
gas supply line. Wait a few minutes for gas to move
through the gas line.
Leak testing
of the appliance
shah be conducted
according
to the manufacturer's
instructions.
Check for leaks. After connecting the range to the gas supply,
check the system for leaks with a manometer. If a manometer
is not available, turn on tile gas supply and use a liquid leak
detector at all joints and connections to check for leaks.
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame
may result in a fire or explosion.
All openings in the wall or floor where tile range is to be
installed must be sealed.
Tighten
all connections
if necessary to prevent gas
leakage in the cooktop or supply line.
Disconnect
this range and its individual
shutoff
valve from tile gas supply piping system during any
pressure testing of tile system at test pressures greater
than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).
Isolate the range from the gas supply piping
system
by closing its individual manual shutoff valve during any
pressure testing of tile gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa or
14"(35,56 cm) water column).
LPiPropane
Gas Conversion
This appliance can be used with Natural gas or LP/Propane
gas. It isshipped from the factory for usewith natural gas.
If you wish to convert your range for use with LP/Propane
gas, use the supplied fixed orifices located in a bag
containing the literature marked "FOR LP/PROPANEGAS
CONVERSION." Follow the instructions packaged with
the orifices.
The conversion must be performed by a qualified service
technician in accordance with the manufacturer's
instructions and all local codes and requirements. Failure
to follow these instructions could result in serious injury
or property damage. The qualified agency performing
this work assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in personal injury and property
damage.

Hide quick links: