Download Print this page

GE JKP90BM4BB Installation Instructions

27" & 30" electric built-in wall ovens

Advertisement

Available languages

Available languages

Quick Links

Installation Instructions
27"& 30" Electric Built-InWall Ovens
Questions?
Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions
completely
and
carefully.
° IMPORTANT
-- Save these
instructions for local inspector's use.
° IMPORTANT
--
Observe all
governing codes and ordinances.
Note to Installer-
Be sure to leave these
instructions
with Consumer.
Note to Consumer-
Keep these
instructions
for future reference.
Skill level - Installation of this appliance
requires a qualified installer or electrician.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under Warranty.
ATTENTION
INSTALLER:
All electric wall ovens must be hard-wired
(direct-wired)
into an approved junction box. A plug and receptacle
is NOT permitted on these products.
FOR YOUR SAFETY:
^,u, WARN ING:
Before beginning the installation, switch power off at the service
panel and lock the service disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure.
Weight on the oven door could cause the oven to tip and result in injury. Never allow anyone to climb,
sit, stand or hang on the oven door.
Make sure the wall coverings, counters and cabinets around the oven can withstand the heat
(up to 200°F [93.3°C]) generated by the oven.
MATERIALS
YOU MAY NEED
Junction Box
Wire Nuts
Strain Relief Clamp for 1/2" Conduit
36" (91 cm) of String
TOOLS
YOU
MAY
NEED
1/8" Drill Bit and Electric or Hand Drill
Phillips Screwdriver
Wire Strippers
[_
REMOVE
PACKAGING
MATERIALS
Failure to remove packaging materials could result in damage to the appliance. Remove all
packing parts from oven, racks and heating elements. Remove protective film and labels on the
outer door and control panel. Also, remove plastic on trims and panel, all tape around the oven
and any shipping screws securing the oven to the base pad. Open oven door and remove
literature pack and oven racks. Remove the bottom trim from the top of the oven. It will be
installed at the end of the installation process. The trim is wrapped separately and taped
to the top of the unit.
_--]_"]
CUTOUT
FOR DOUBLE
OVENS
(2 Thermal Ovens)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾" (1.9 cm) thick,
shim both sides equally to establish the cutout width.
--_
H
_-
F
G"
................ A_
i _
Junction
Box
Location
(junction
box
may be
located
J
in adjacent
cal_inet)
eli
Dimension
Dimension Description
27" Double Oven
30" Double Oven
A
Cabinet
Width
27" (68.6 cm)
30" (76.2 cm)
B
Cutout
Width
25" (63.5 cm) min.
28½" (72.4 cm) min.
25¼" (64.1 cm) max.
28%" (72.7 cm) max.
C
Cutout
Height
49_6 '' (126.2 cm) min.
51_%6'' (131.6 cm) min.
50½" (127.3 cm) max.
51_%6'' (131.9 cm) max.
D
Overlap
of Oven
1" (2.5 cm)
_6" (1.75 cm)
Over Side Edges
of Cutout
E
Clearance
to Adjacent
20" (50.8 cm) min.
21" (53.3 cm) min.
Corners, Drawers, Walls,
etc., When Door Is Open
F
Overlap
of Oven
1" (2.5 cm) min.
1" (2.5 cm) min.
Top of Cutout
G
Overlap
of Oven
1" (2.5 cm) min.
1¼" (3.2 cm)
Bottom
of Cutout
H
Junction
Box Location
8¾" (22.2 cm) max.
9½" (24.1 cm) max.
right side only
right side only
J
Height to Bottom
of
44" (111.8 cm)
47" (119.4 cm)
Junction
Box
K
Recommended
13¼" (33.7 cm)
12" (30.5 cm)
Cutout
Location
from
Floor
Continue
to Section
3.
31-10730-1 I 08-09 JR
DESIGN
INFORMATION
SINGLE OVEN INSTALLATIONS
The single oven may be installed in a cabinet alone or above a warming drawer. The single oven may
also be installed below a countertop or below specified cooktops. See the label on top of the oven for
approved models.
DOUBLE OVEN INSTALLATIONS
A double oven may be installed in a cabinet alone or above a warming drawer. See the label on top of
the oven for approved models.
IMPORTANT: Always refer to individual installation instructions packed with each product for specific
requirements.
E_
PREPARE
THE OPENING
(FOR INDOOR
USE ONLY)
NOTE: If the cabinet does not have a solid bottom,
two braces or runners must be installed to support
the weight of the oven. For single ovens, the runners
and braces must support 200 Ibs (91 kg). For double
ovens, the runners and braces must support 375 Ibs.
(170 kg).
NOTE: If marks, blemishes
or the cutout opening are
visible above the installed oven, it may be necessary
to add wood shims under the runners and front trim
until the marks or opening are covered.
NOTE: If the cabinet does not have a front frame
and the sides are less than ¾" (1.9 cm) thick, shim
both sides equally to establish the cutout width.
2" x4"(5cmxtOcm)
or Equivalent
Runners
Level
with
Bottom
of Cutout
Suitable
Bracing
to Support
Runners
I
21 5/8"
(54.9 cm) Over
/
Centerline
of Cabinet
E_[_]
CUTOUT
FOR DOUBLE
OVENS (with Upper
MicrowaveOven)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾" (1.9 cm) thick,
shim both sides equally to establish the cutout width.
H
Junction BOX
Location
/ (junction
box
/
may be
located
in adjacent
cabinet)
C
28" (71.1
cm)
Min.
to Bottom
Of
. -"
Cutout
Depth
= 23 1/2"
_.........__,_/(59.7
cm)
Minimum
Cutout
Location
I
From Floor
A
Dimension
27" Oven
30" Oven
Dimension
Description
with Microwave
with Microwave
A
Cabinet Width
27" (68.6 cm)
30" (76.2 cm)
B
Cutout
Width
25" (63.5 cm) min.
28½" (72.4 cm) min.
25¼" (64.1 cm) max.
28%" (72.7 cm) max.
C
Cutout
Height
41½" (104.5 cm) min.
42%6" (107.2 cm) min.
41¼" (104.8 cm) max.
42¼" (107.3 cm) max.
D
Overlap
of Oven
1" (2.5 cm)
_6"
(1.75 cm)
Over Side Edges
of Cutout
E
Clearance
to Adjacent
20" (50.8 cm) min.
21" (53.3 cm)
Corners, Drawers, Walls,
etc., When Door Is Open
F
Overlap
of Oven
1" (2.5 cm) min.
1" (2.5 cm) min.
Top of Cutout
G
Overlap
of Oven
1" (2.5 cm) min.
1¼" (3.2 cm)
Bottom
of Cutout
H
Junction
Box Location
8¾" (22.2 cm) max.
9½" (24.1 cm) max.
right side only
right side only
Continue
to Section
3.
r21rA-i
CUTOUT
FOR SINGLE
OVENS
IN WALL
CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than ¾" (1.9 cm) thick,
shim both sides equally to establish the cutout width.
H
I
These ovens are not
I
approved for stackable
I
installations.
Side-by-Side
Installations
(30" only)
" - -- - - -.
Install two ovens in separate
cutouts,
Center
Line
Center
Line
I
I
I
30.5" (77.5
cm)
I
!
!
I
Cutout
observe all
dimensions
and
requirements,
I
Cutout
1
observe all
dimensions
and
requirements,
I-4[,--
2" (5,1 cm) Min,
*--- B --.
Wails Must
Be at Least
28 1/2"
(72.4 cm)
Junction
Box
Location
(junction
box
may
be
located
in adjacent
cabinet)
22" (55.9
cm)
C
Min. To
Bottom
of
Junction
Box
Recommended
u
Cutout
Location
From
Floor
32 t12" (82.8
cm)
Cutout Depth - 23 t/2"
(59,7 cm) Minimum
Dimension
Dimension Description
27" Single
Oven
30" Single
Oven
A
Cabinet Width
27" (68.6 cm)
30" (76.2 cm)
B
Cutout
Width
25" (63.5 cm) min.
28½" (72.4 cm) min.
25¼" (64.1 cm) max.
28%" (72.7 cm) max.
C
Cutout
Height
27%" (70.2 cm) min.
27¼" (69.2 cm) min.
28½" (71.4 cm) max.
27%6" (69.4 cm) max.
D
Overlap
of Oven Over
1" (2.5 cm)
_½6" (1.75 cm)
Side Edges of Cutout
E
Clearance
to
20" (50.8 cm) min.
21" (53.3 cm) min.
Adjacent
Corners,
Drawers,
Walls, etc.,
When Door Is Open
F
Overlap
of Oven
1" (2.5 cm) min.
1" (2.5 cm) min.
Top of Cutout
G
Overlap
of Oven
1" (2.5 cm) min.
1¼" (3.2 cm)
Bottom
of Cutout
H
Junction
Box Location
8%" (22.2 cm) max.
9½" (24.1 cm) max.
right side only
right side only
_--][_
CUTOUT
FOR INSTALLATION
OVER A WARMING
DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances
between cutouts may be required. Check to be sure the oven
supports above the Warming Drawer location do not obstruct the required interior depth and
height.
When installing a Warming Drawer below a single or double oven, a separate
120V, 60 HZ,
properly grounded receptacle
must be installed. Refer to installation instructions
packed with
the Warming Drawer for specific installation requirements.
Anti-Tip
Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
Continue
to Section 3.
12-11-B-ICUTOUTFORSINGLE
OVENS-UNDER
COUNTER
NOTE: These ovens are only approved to be installed under the specific models as labeled on
the unit.
Gas or Electric
Cooktops
May
Be installed
Over This Oven.
See Cooktop
Installation
instructions
for Cutout Size,
240V/208V
See Label
on Top of Oven for Approved
Models,
Junction
Box
Location
(junction
box may be
in adjacent
cabinet)
25" (63.5 cm)
Gas and
Electrical
Connections
for Gas Cooktop
Must be Located
in an Ad acent
Accessible
Locat
on to the Right
MUST
SUPPORT
200 Ibs. (90 kg) FOR SINGLE
OVENS
MUST
SUPPORT
375 Ibs, (170 kg) FOB DOUBLE
OVENS
Cutout - observe
all dimensions
and
requirements.
Side-by-Side
Installations (30" only)
Install two ovens in separate cutouts.
Center Line
Center Line
30.5" (77.5 cm)
I
',_
_I
I
I
I
I
Cutout-
observe
I
all dimensions
and
I
requirements.
'_1
I_
2" (5,1 ore) Min,
22" (55.9 cm) Min.
36" (91.4 crn)
Above Support
Platform
Countertop
Height
4" (t0.2
cm)
Toeklck
NOTE: One cooktop may be centered over either
oven in the side-by-side
installation.
Dimension
Dimension Description
27" Single
Oven
30" Single
Oven
A
Cabinet Width
25" (63.5 cm) min.
28½" (72.4 cm) rain.
25¼" (64.1 cm) max.
28%" (72.7 cm) max.
B
Cutout
Height
27%" (70.2 cm) min.
27¼" (69.2 cm) min.
28½" (71.4 cm) max.
27%6" (69.4 cm) max.
C
Unit Overlap
Top
1" (2.5 cm)
1" (2.5 cm)
D
Unit Overlap
Bottom
1" (2.5 cm)
1¼" (3.2 cm)
E
Unit Overlap
Side Edges
1" (2.5 cm)
_6"
(1.75 cm)
F
Junction
Box Location
8¾" (22.2 cm) max.
9½" (24.1 cm) max.
right side only
right side only
Continue
to Section
3.

Advertisement

loading

Summary of Contents for GE JKP90BM4BB

  • Page 1 See the label on top of the oven for Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com approved models. Gas or Electric...
  • Page 2 Remove the string available for your model. To check availability or order parts, call 1.800.GE.CARES. DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached by pulling on one end of the We recommend you have the electrical wiring and hookup of your appliance connected by a to the junction box and the flexible conduit must be securely attached to the clamp.
  • Page 3 (1,9 cm), coloque cutlas uniformemente sobre ambos lades para establecer al ancho de la abertura. etiqueta de la unidad. tambi_n puede instalarse debajo de un mostrador de encimera o debajo de las estufas especificadas. _Preguntas? Llame al 1.800.GE.CARES (1.800.432.2737) o visite GEAppliances.com Pueden...
  • Page 4 Una conexi6n inadecuada de cableado dom6stico de empuja el uno disponiblepara su modelo. Para verificarla disponibilidado solicitar piezas, Ilame al 1.800.GE.CARES. hacia arras, jale del hilo para NO acorte el conducto flexible. La abrazadera del alivio de tensi6n del conducto debe estar bien sujeta homo dentro aluminio con cables de cobre puede generar un peligro el6ctrico o un incendio.

This manual is also suitable for:

Jkp90wm4wwJkp90cm4ccPt916sr2ssPt956dr2wwPt900dr2wwPk956dr3ww ... Show all